EUVIMEDEUVIMED entdecken
Crossref

Multi‐Metric Evaluation of a Green HPLC‐PDA Method for Sibutramine Quantification in Herbal Teas

Burcu Sezgin iD, Murat Soyseven iD, Göksel Arli iD

Biomedical Chromatography · 2026

DOI: 10.1002/bmc.70318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2026. Verfasst von Burcu Sezgin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Protection Technologies, Eskişehir Vocational School, Eskişehir Osmangazi University, Eskişehir, Turkey. Hauptthemen laut MEDLINE: Cyclobutanes, Teas, Herbal. Die Arbeit nennt 66 Literaturangaben. Gefördert von: Anadolu University, Anadolu Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sibutramine (SBT) is a synthetic anorectic agent formerly prescribed for obesity but withdrawn due to cardiovascular risks. Its illicit addition to herbal weight‐loss products remains a major health concern. This study reports the development and validation of a green, rapid, and sensitive HPLC‐PDA method for SBT quantification in herbal teas. Separation was performed on a C18 reversed‐phase column (150 × 4.6 mm, 5 μm) using ethanol:water (35:65, v/v) acidified to pH 3.0 with orthophosphoric acid, under isocratic conditions (2.0 mL/min, 40°C, 10‐min runtime). A matrix‐matched calibration strategy was employed to minimize matrix effects. The method showed excellent linearity ( R 2 = 0.9987) within 1.00–30.00 μg mL −1 , with LOD and LOQ of 0.06 and 0.20 μg mL −1 . The validation of the method, rigorously conducted in accordance with the ICH Q2(R2) guidelines, unequivocally confirmed its high accuracy, reproducibility, and robustness across multiple experimental conditions. Comprehensive multi‐metric assessments further demonstrated the method's outstanding analytical performance, remarkable applicability, and notable environmental sustainability. Taken together, these results underscore that the method is not only highly reliable and precise but also eco‐conscious, making it exceptionally well suited for routine screening and monitoring of complex herbal matrices, fully aligning with the principles of white analytical chemistry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CyclobutanesTeas, HerbalChromatography, High Pressure LiquidReproducibility of ResultsLinear ModelsLimit of Detection

Stichwörter der Autor:innen

HPLC‐PDAgreen analytical chemistryherbal teasibutraminewhite analytical chemistry

Substanzen

sibutramineCyclobutanesTeas, Herbal

Autor:innen und Institutionen

  • Department of Environmental Protection Technologies, Eskişehir Vocational School, Eskişehir Osmangazi University, Eskişehir, Turkey.
  • Department of Medical Services and Techniques, Yunus Emre Vocational School of Health Services, Anadolu University, Eskişehir, Turkey.
  • Department of Analytical Chemistry, Faculty of Pharmacy, Anadolu University, Eskişehir, Turkey.

ORCID-Profile: Burcu Sezgin, Murat Soyseven, Göksel Arli

Förderung

  • Anadolu University
  • Anadolu Üniversitesi

Zitieren

APA

Sezgin, B., Soyseven, M., & Arli, G. (2026). Multi‐Metric Evaluation of a Green HPLC‐PDA Method for Sibutramine Quantification in Herbal Teas. Biomedical Chromatography. https://doi.org/10.1002/bmc.70318

Vancouver

Sezgin B, Soyseven M, Arli G. Multi‐Metric Evaluation of a Green HPLC‐PDA Method for Sibutramine Quantification in Herbal Teas. Biomedical Chromatography. 2026. doi:10.1002/bmc.70318

BibTeX
@article{Sezgin2026,
  author = {Sezgin, Burcu and Soyseven, Murat and Arli, Göksel},
  title = {Multi‐Metric Evaluation of a Green HPLC‐PDA Method for Sibutramine Quantification in Herbal Teas},
  journal = {Biomedical Chromatography},
  year = {2026},
  doi = {10.1002/bmc.70318}
}
Kostenlos starten →