RP‐HPLC–Validated Method for Hesperidin Estimation in Rat Skin Following Transdermal Delivery via Dissolving Microneedle Patch

Gopika Gopan, Jobin Jose iD, Kartik Bhairu Khot

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70257 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Gopika Gopan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutics, NGSM Institute of Pharmaceutical Sciences, Nitte (deemed to be University), Mangalore, Karnataka, India. Hauptthemen laut MEDLINE: Skin, Hesperidin, Chromatography, Reverse-Phase. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for validating the amount of HES in dissolving microneedle patches (DMNs) loaded with HES‐based nanostructured lipid carriers (HES‐NLC)s has been developed. The method was developed and validated according to the guidelines published by the International Council for Harmonization (ICH), using a mobile phase of methanol:water (90:10 v/v) at a flow rate of 0.5 mL/min, with UV detection at 284 nm. This method demonstrated accuracy from 94% to 108%, with a precision of 2% across all evaluated concentrations, along with high selectivity, sensitivity, and stability for transdermal application studies. The method also showed good linearity in rat plasma and skin homogenate, with no interference from biological matrices, which aligns with FDA guidelines. Permeation studies revealed enhanced HES delivery via DMNs with nearly 20‐fold higher drug deposition compared to passive diffusion. Pretreatment with DMNs significantly boosted the transdermal permeation of HES (112.86 ± 23.58 μg/cm 2 after 24 h, p < 0.01), by increased flux (1.31 ± 0.11 μg/cm 2 /h) and permeability coefficient (0.36 × 10 − 6 cm/s) values. This validated method offers a promising tool for advancing transdermal evaluation in innovative pharmaceutical formulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SkinHesperidinChromatography, Reverse-PhaseAnimalsChromatography, High Pressure LiquidRatsAdministration, CutaneousReproducibility of ResultsMaleNeedlesSkin AbsorptionLinear ModelsLimit of DetectionRats, Sprague-DawleyTransdermal PatchRats, Wistar

Stichwörter der Autor:innen

dissolving microneedlehesperidinmethod validationnanostructured lipid carriersreverse‐phase high‐performance liquid chromatographytransdermal delivery

Substanzen

Hesperidin

Autor:innen und Institutionen

  • Department of Pharmaceutics, NGSM Institute of Pharmaceutical Sciences, Nitte (deemed to be University), Mangalore, Karnataka, India.

ORCID-Profile: Jobin Jose

Zitieren

APA

Gopan, G., Jose, J., & Khot, K. B. (2025). RP‐HPLC–Validated Method for Hesperidin Estimation in Rat Skin Following Transdermal Delivery via Dissolving Microneedle Patch. Biomedical Chromatography. https://doi.org/10.1002/bmc.70257

Vancouver

Gopan G, Jose J, Khot KB. RP‐HPLC–Validated Method for Hesperidin Estimation in Rat Skin Following Transdermal Delivery via Dissolving Microneedle Patch. Biomedical Chromatography. 2025. doi:10.1002/bmc.70257

BibTeX
@article{Gopan2025,
  author = {Gopan, Gopika and Jose, Jobin and Khot, Kartik Bhairu},
  title = {RP‐HPLC–Validated Method for Hesperidin Estimation in Rat Skin Following Transdermal Delivery via Dissolving Microneedle Patch},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70257}
}
Kostenlos starten →