EUVIMEDEUVIMED entdecken
Crossref

Validated HPLC Method for the Pharmacokinetic Study of Linezolid in Rats

Jin-Yao Liu iD, Ying-Ying Pang, Piao-Piao Wang, Wen-Yan Li, Jing Dong

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70107 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Jin-Yao Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Training Base at Shanghai Gongli Hospital, Ningxia Medical University, Shanghai, China. Hauptthemen laut MEDLINE: Linezolid, Anti-Bacterial Agents. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Shanghai Municipal Health commission, Medical Discipline Construction Program of Shanghai Pudong New Area Health Commission, Academic Leaders Training Program of shanghai Pudong New Area Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Linezolid is an oxazolidinone with potent antibacterial activity against multidrug resistant Gram‐positive bacteria. This study aimed to develop and validate a sensitive, rapid and reliable high‐performance liquid chromatography‐photodiode array detector method for determining linezolid concentrations in the plasma and urine and to further characterize the pharmacokinetics of linezolid in rats. Chromatographic separation was performed using a SinoPak BEH C 18 column with isocratic elution (acetonitrile: water, 28:72, v/v). The retention times of linezolid and the internal standard are 3.30 and 5.20 min, respectively. The calibration curve for linezolid was linear over the concentration range of 0.25–50.0 μg/mL in rat plasma and 1.00–100.0 μg/mL in rat urine. Intra‐ and inter‐assay precision values were below 9.00%, with accuracy ranging from 0.67% to 8.34%. Plasma samples were extracted using acetonitrile‐mediated protein precipitation, and the recovery was > 93%. Following intragastric (63 mg/kg) and intravenous (25 mg/kg) administration of linezolid to rats, the area under the plasma concentration–time profile from time 0 to infinity were 224.5 and 86.4 μg·h/mL, total clearance were 0.29 and 0.30 L/h/kg, respectively. The cumulative urinary excretion rates of linezolid were 26.2%–27.5% for both administration routes. The presented method can certainly be used for routine analysis of linezolid in plasma and urine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LinezolidAnti-Bacterial AgentsAnimalsChromatography, High Pressure LiquidRatsMaleReproducibility of ResultsRats, Sprague-DawleyLinear ModelsLimit of DetectionSensitivity and SpecificityDrug Stability

Stichwörter der Autor:innen

HPLClinezolidmethod validationpharmacokinetics

Substanzen

LinezolidAnti-Bacterial Agents

Autor:innen und Institutionen

  • Postgraduate Training Base at Shanghai Gongli Hospital, Ningxia Medical University, Shanghai, China.
  • Department of Pharmacy, Shanghai Pudong New Area Gongli Hospital, Shanghai, China.

ORCID-Profile: Jin-Yao Liu

Förderung

  • Shanghai Municipal Health commission
  • Medical Discipline Construction Program of Shanghai Pudong New Area Health Commission
  • Academic Leaders Training Program of shanghai Pudong New Area Health Commission

Zitieren

APA

Liu, J. Y., Pang, Y. Y., Wang, P. P., Li, W. Y., & Dong, J. (2025). Validated HPLC Method for the Pharmacokinetic Study of Linezolid in Rats. Biomedical Chromatography. https://doi.org/10.1002/bmc.70107

Vancouver

Liu JY, Pang YY, Wang PP, Li WY, Dong J. Validated HPLC Method for the Pharmacokinetic Study of Linezolid in Rats. Biomedical Chromatography. 2025. doi:10.1002/bmc.70107

BibTeX
@article{Liu2025,
  author = {Liu, Jin-Yao and Pang, Ying-Ying and Wang, Piao-Piao and Li, Wen-Yan and Dong, Jing},
  title = {Validated HPLC Method for the Pharmacokinetic Study of Linezolid in Rats},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70107}
}
Kostenlos starten →