EUVIMEDEUVIMED entdecken
Crossref

A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry

Yihong Jiang, Yaling Niu, Congchao Ning, Feng Qin iD, Chengda Yan, Xiumei Lu

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Yihong Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Shenyang Pharmaceutical University, Shenyang, Liaoning Province, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Bisoprolol. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben. Gefördert von: Undergraduate Training Program for Innovation and Entrepreneurship of Shenyang Pharmaceutical University, Middle-Aged Backbone Personnel Training Program of Shenyang Pharmaceutical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A rapid and sensitive ultra‐high performance liquid chromatography–tandem mass spectrometry (UHPLC‐MS/MS) method for the determination of bisoprolol in human plasma was established and validated. The sample was pretreated by methanol precipitation protein, and the isotope bisoprolol‐d 5 was used as the internal standard. The chromatographic column was ACQUITY UPLC BEH‐C 18 column (2.1 × 50 mm, 1.7 μm), with methanol and 0.2% formic acid aqueous solution as mobile phase for gradient elution. The electrospray ionization (ESI) source was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was used. The total running time was only 2.00 min. The correlation coefficient was good ( r > 0.99) in the linear range of 0.0200–40.0 ng/mL. The lower limit of quantitation (LLOQ) was 20.0 pg/mL. The intrabatch and interbatch precisions were not more than 8.9% and 9.2%. The intrabatch and interbatch accuracies were −7.9% ~ 6.3% and −6.9% ~ 5.0%. The method was fully validated including whole blood stability and reinjection reproducibility and successfully applied to the pharmacokinetic study of 5‐mg bisoprolol in healthy volunteers, which 93.1% incurred samples reanalysis (ISR) met the criteria. Compared with the reported methods, this method had the highest sensitivity and fast analysis speed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryBisoprololHumansChromatography, High Pressure LiquidReproducibility of ResultsLinear ModelsLimit of DetectionMaleSensitivity and SpecificityDrug StabilityAdult

Stichwörter der Autor:innen

UHPLC‐MS/MSbisoprololpharmacokineticsplasma

Substanzen

Bisoprolol

Autor:innen und Institutionen

  • Shenyang Pharmaceutical University, Shenyang, Liaoning Province, China.
  • The First Hospital of China Medical University, Shenyang, Liaoning Province, China.

ORCID-Profile: Feng Qin

Förderung

  • Undergraduate Training Program for Innovation and Entrepreneurship of Shenyang Pharmaceutical University
  • Middle-Aged Backbone Personnel Training Program of Shenyang Pharmaceutical University

Zitieren

APA

Jiang, Y., Niu, Y., Ning, C., Qin, F., Yan, C., & Lu, X. (2025). A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry. Biomedical Chromatography. https://doi.org/10.1002/bmc.70054

Vancouver

Jiang Y, Niu Y, Ning C, Qin F, Yan C, Lu X. A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry. Biomedical Chromatography. 2025. doi:10.1002/bmc.70054

BibTeX
@article{Jiang2025,
  author = {Jiang, Yihong and Niu, Yaling and Ning, Congchao and Qin, Feng and Yan, Chengda and Lu, Xiumei},
  title = {A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography–Tandem Mass Spectrometry},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70054}
}
Kostenlos starten →