EUVIMEDEUVIMED entdecken
Crossref

Stability‐indicating RP‐HPLC method development and validation for the quantification of amlodipine besylate and valsartan tablets in solid oral dosage form

Teja Kamireddy, Pranitha Sambu iD, Prasanna Kumar Lankalapalli iD, Rama Krishna Myneni, Hareesh Divadari

Biomedical Chromatography · 2024

DOI: 10.1002/bmc.6017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2024. Verfasst von Teja Kamireddy und 4 weiteren Autor:innen. Beteiligte Einrichtung: August Bioservices, 1845 Elm Hill Pike, Nashville, TN, 37210, USA. Hauptthemen laut MEDLINE: Amlodipine, Valsartan, Drug Stability, Tablets. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study discusses the development of simple, rapid, specific, precision, accuracy, stability indicating the HPLC method for the analysis of amlodipine besylate and valsartan tablet dosage form. The chromatographic separation was achieved using phosphate buffer with 1% triethyl amine (pH 3.0) as mobile phase‐A and mixed Methanol and buffer in the ratio of (65:35)(v/v) as mobile phase‐B. The detection of components was made at 237 nm for amlodipine besylate and valsartan. Analytical techniques should enrich sensitivity and specificity for the estimation of pharmaceutical drug products. Evaluated stress studies under different types of ICH conditions. The optimized HPLC method was validated as per the current ICH guidelines. The validated HPLC method was obtained highly specific with linearity ranging between 25 and 200 μgmL −1 of amlodipine besylate and 40–320 μgmL −1 of valsartan and both components correlation coefficient was > 0.999. The method showed high accuracy more than 97%. In stress studies, amlodipine besylate and valsartan were found to be sensitive to acid stress conditions and oxidation stress conditions. The method was found to be suitable for the quality control of amlodipine besylate and valsartan in the tablet as well as in stability‐indicating studies. The method was applied to the analysis of stability samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmlodipineValsartanDrug StabilityTabletsChromatography, Reverse-PhaseLimit of DetectionChromatography, High Pressure LiquidReproducibility of ResultsLinear Models

Stichwörter der Autor:innen

HPLCPDAamlodipine besylatemethod developmentvalidationvalsartan

Substanzen

AmlodipineValsartanTablets

Autor:innen und Institutionen

  • August Bioservices, 1845 Elm Hill Pike, Nashville, TN, 37210, USA.
  • Aurex Laboratories Pvt Ltd. Prashanthi nagar, Kukatpally, Hyderabad, India.
  • Visual Technologies LLC, 5851 Legacy Circle, Plano, TX, 75024, USA.
  • Stira pharmaceuticals LLC, 161, Dwight place, Fairfield, New Jersey, 07004, USA.

ORCID-Profile: Pranitha Sambu, Prasanna Kumar Lankalapalli

Zitieren

APA

Kamireddy, T., Sambu, P., Lankalapalli, P. K., Myneni, R. K., & Divadari, H. (2024). Stability‐indicating RP‐HPLC method development and validation for the quantification of amlodipine besylate and valsartan tablets in solid oral dosage form. Biomedical Chromatography. https://doi.org/10.1002/bmc.6017

Vancouver

Kamireddy T, Sambu P, Lankalapalli PK, Myneni RK, Divadari H. Stability‐indicating RP‐HPLC method development and validation for the quantification of amlodipine besylate and valsartan tablets in solid oral dosage form. Biomedical Chromatography. 2024. doi:10.1002/bmc.6017

BibTeX
@article{Kamireddy2024,
  author = {Kamireddy, Teja and Sambu, Pranitha and Lankalapalli, Prasanna Kumar and Myneni, Rama Krishna and Divadari, Hareesh},
  title = {Stability‐indicating RP‐HPLC method development and validation for the quantification of amlodipine besylate and valsartan tablets in solid oral dosage form},
  journal = {Biomedical Chromatography},
  year = {2024},
  doi = {10.1002/bmc.6017}
}
Kostenlos starten →