Optimization and validation of high‐performance liquid chromatography using modified QuEChERS to determine anthelmintic drugs in mutton
Biomedical Chromatography · 2024
DOI: 10.1002/bmc.5814 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Chromatography, 2024. Verfasst von Hiwa Muhammad Husein Hiwa und 1 weiteren Autor:innen. Beteiligte Einrichtung: Sulaimaniyah New Slaughterhouse, Sulaimaniyah Directorate of Veterinary Medicine, Sulaimaniyah, Kurdistan Region, Iraq. Hauptthemen laut MEDLINE: Ivermectin, Anthelmintics, Salicylanilides. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
The aim of this study was to rapidly determine the presence of anthelmintic drugs in sheep meat using the optimized high‐performance liquid chromatography‐ultraviolet (HPLC‐UV) method with modified QuEChERS (quick, easy, cheap, effective, rugged, safe) technology. Fifty fresh sheep meat samples from different slaughterhouses were collected. A double extraction procedure (QuEChERS/HPLC‐UV technology) was used to extract the target analytes. A multilevel calibration curve from 1 to 1000 g/kg was used to establish instrument linearity for rafoxanide, albendazole, and closantel, whereas 0.1–100 μg/kg was used for ivermectin, levamisole, and oxyclozanide to find the lowest concentration, maximum residue limit (MRL), and occupied range for targeted analytes. The concentration levels were used to investigate the linearity, whereas several certified reference materials were applied to determine accuracy. The process was linear for all combinations, from the limit of quantification (LOQ) to the maximum concentration. The LOQ was established at 0.5 μg/kg for ivermectin, levamisole, and oxyclozanide and 10 μg/kg for rafoxanide, albendazole, and closantel. Recovery values were 70%–120%, and repeatability/reproducibility stated in relative standard deviation was obtained at less than 20%. QuEChERS method revealed that most meat samples contained anthelmintic drug residues, of which the majority exceeded the MRLs. Thus, the drugs should be used correctly in animals to avoid residues in food for human consumption.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Sulaimaniyah New Slaughterhouse, Sulaimaniyah Directorate of Veterinary Medicine, Sulaimaniyah, Kurdistan Region, Iraq.
- Department of Microbiology, College of Veterinary Medicine, University of Sulaimani, Old Campus, Sulaymaniyah, Kurdistan Region, Iraq.
- Department of Food Science and Quality Control, College of Agricultural Engineering Sciences, University of Sulaimani, Awall Street, Bakrajo, Bakrajo Campus, Sulaymaniyah, Kurdistan Region, Iraq.
ORCID-Profile: Hiwa Muhammad Husein Hiwa
Zitieren
APA
Hiwa, H. M. H., & Khulod, K. I. H. (2024). Optimization and validation of high‐performance liquid chromatography using modified QuEChERS to determine anthelmintic drugs in mutton. Biomedical Chromatography. https://doi.org/10.1002/bmc.5814
Vancouver
Hiwa HMH, Khulod KIH. Optimization and validation of high‐performance liquid chromatography using modified QuEChERS to determine anthelmintic drugs in mutton. Biomedical Chromatography. 2024. doi:10.1002/bmc.5814
BibTeX
@article{Hiwa2024,
author = {Hiwa, Hiwa Muhammad Husein and Khulod, Khulod Ibraheem Hassan},
title = {Optimization and validation of high‐performance liquid chromatography using modified QuEChERS to determine anthelmintic drugs in mutton},
journal = {Biomedical Chromatography},
year = {2024},
doi = {10.1002/bmc.5814}
}
EUVIMED