EUVIMEDEUVIMED entdecken
Crossref

Bioanalytical liquid chromatography–tandem mass spectrometry method development and validation for quantification of lurasidone in rat plasma using ion pairing agent

Madhura Rajadhyaksha iD, Vaishali Londhe

Biomedical Chromatography · 2024

DOI: 10.1002/bmc.5764 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2024. Verfasst von Madhura Rajadhyaksha und 1 weiteren Autor:innen. Beteiligte Einrichtung: SPPSPTM, SVKM's Narsee Monjee Institute of Management Studies, Mumbai, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Lurasidone Hydrochloride. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A bioanalytical method was developed and validated for determining lurasidone (LUR) in rat plasma. The analyte and internal standard were extracted from rat plasma using a liquid–liquid extraction method. The mobile phase consisted of methanol, acetonitrile and water, with an ion pairing agent, 0.1% heptafluorobutyric acid, added to minimise the matrix effect. The detection was achieved using a tandem mass spectrometer (API 2000) in positive ion multiple reaction monitoring mode. All parameters were validated, including selectivity, specificity, carry‐over effect, linearity, precision, accuracy, matrix effect, sensitivity and stability. The linearity range was from 5.0 to 1200.0 ng/mL with a correlation coefficient of >0.99. The accuracy ranged from 100.00% to 110.22% across the quality control range. The mean absolute recovery from matrix samples for LUR and the internal standard was found to be 68.46% and 67.25%, respectively, and the relative recovery was found to be 73.89% and 77.44%, respectively. This method can determine LUR concentrations in rat plasma samples up to 12 h after oral administration, aiding in LUR pharmacokinetic (PK) investigations in rats. The method's reproducibility on a conventional LC–MS/MS system and a shorter run time of 3.0 min make it an appealing bioanalytical method for quantifying LUR in PK studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLurasidone HydrochlorideRatsAnimalsChromatography, LiquidChromatography, High Pressure LiquidReproducibility of Results

Stichwörter der Autor:innen

liquid chromatographylurasidonerat plasmatandem mass spectrometry

Substanzen

Lurasidone Hydrochloride

Autor:innen und Institutionen

  • SPPSPTM, SVKM's Narsee Monjee Institute of Management Studies, Mumbai, India.
  • Sitec Labs Ltd., Mumbai, India.

ORCID-Profile: Madhura Rajadhyaksha

Zitieren

APA

Rajadhyaksha, M., & Londhe, V. (2024). Bioanalytical liquid chromatography–tandem mass spectrometry method development and validation for quantification of lurasidone in rat plasma using ion pairing agent. Biomedical Chromatography. https://doi.org/10.1002/bmc.5764

Vancouver

Rajadhyaksha M, Londhe V. Bioanalytical liquid chromatography–tandem mass spectrometry method development and validation for quantification of lurasidone in rat plasma using ion pairing agent. Biomedical Chromatography. 2024. doi:10.1002/bmc.5764

BibTeX
@article{Rajadhyaksha2024,
  author = {Rajadhyaksha, Madhura and Londhe, Vaishali},
  title = {Bioanalytical liquid chromatography–tandem mass spectrometry method development and validation for quantification of lurasidone in rat plasma using ion pairing agent},
  journal = {Biomedical Chromatography},
  year = {2024},
  doi = {10.1002/bmc.5764}
}
Kostenlos starten →