EUVIMEDEUVIMED entdecken
Crossref

Dissipation kinetics, residue determination and consumer risk assessment of acephate on green pea by gas chromatography–electron capture detector

Ishrat Jan iD, Alamgir A Dar, Malik Mukhtar, Mehraj D Shah, Ashraf A Wani, Shahnawaz R Dar, Irshad H Dar, Javid A Sofi

Biomedical Chromatography · 2023-10 · 37 (10)

DOI: 10.1002/bmc.5705 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 31.07.2023. Verfasst von Ishrat Jan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Centre for Residue and Quality Analysis, Sher-e-Kashmir University of Agricultural Sciences and Technology (SKUAST-K), Srinagar, India. Hauptthemen laut MEDLINE: Pisum sativum, Pesticide Residues. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Indian Council of Agricultural Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study on “acephate persistence on green pea” was conducted in SKUAST‐Kashmir. The study aimed to determine the persistence, dissipation kinetics and waiting period of acephate on green pea. Acephate was sprayed at 75% soluble powder (SP) at 560 g a.i.ha −1 at the fruiting stage followed by another application at a 10 day interval. A rapid and accurate method (quick, easy, cheap, effective, rugged and safe, QuEChERS) was used for extraction and the residue was determined by gas chromatography–electron capture detection on a CPSIL‐8CB capillary column (0.25um film thickness, 0.25 mm i.d, 30 m length). At the fortification levels of 0.05, 0.1 and 0.5 mg kg −1 , the percentage recovery of acephate on green pea was found in the range of 71–107%. The initial deposit of green pea was estimated to be 0.37 mg kg −1 . At the indicated dose, the residue of acephate on green pea dissipated below the limit of quantification of 0.05 mg kg −1 after 10 days. Acephate degradation was quick in green pea, with a half‐life of 4.07 days. For safe eating of green peas, a 10 day waiting period is recommended. The gas chromatography–electron capture detection technique was validated by following the SANTE standards.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pisum sativumPesticide ResiduesKineticsElectronsChromatography, GasRisk AssessmentOrganothiophosphorus CompoundsPhosphoramides

Stichwörter der Autor:innen

GC-ECDacephategreen peaquantificationrisk assessment

Substanzen

Pesticide ResiduesacephateOrganothiophosphorus CompoundsPhosphoramides

Autor:innen und Institutionen

  • Research Centre for Residue and Quality Analysis, Sher-e-Kashmir University of Agricultural Sciences and Technology (SKUAST-K), Srinagar, India.

ORCID-Profile: Ishrat Jan

Förderung

  • Indian Council of Agricultural Research

Zitieren

APA

Jan, I., Dar, A. A., Mukhtar, M., Shah, M. D., Wani, A. A., Dar, S. R., Dar, I. H., & Sofi, J. A. (2023). Dissipation kinetics, residue determination and consumer risk assessment of acephate on green pea by gas chromatography–electron capture detector. Biomedical Chromatography, 37(10). https://doi.org/10.1002/bmc.5705

Vancouver

Jan I, Dar AA, Mukhtar M, Shah MD, Wani AA, Dar SR, et al. Dissipation kinetics, residue determination and consumer risk assessment of acephate on green pea by gas chromatography–electron capture detector. Biomedical Chromatography. 2023;37(10). doi:10.1002/bmc.5705

BibTeX
@article{Jan2023,
  author = {Jan, Ishrat and Dar, Alamgir A and Mukhtar, Malik and Shah, Mehraj D and Wani, Ashraf A and Dar, Shahnawaz R and Dar, Irshad H and Sofi, Javid A},
  title = {Dissipation kinetics, residue determination and consumer risk assessment of acephate on green pea by gas chromatography–electron capture detector},
  journal = {Biomedical Chromatography},
  year = {2023},
  volume = {37},
  number = {10},
  doi = {10.1002/bmc.5705}
}
Kostenlos starten →