A Practical Gut‐On‐Chip Workflow for Imaging‐Based Assessment of Epithelial Barrier Dynamics During E. coli Co‐Culture
Biotechnology and Bioengineering · 2026
DOI: 10.1002/bit.70240 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology and Bioengineering, 2026. Verfasst von Shih-Wei Chiang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Colorectal Surgery, Department of Surgery, Taichung Veterans General Hospital, Taichung, Taiwan. Hauptthemen laut MEDLINE: Escherichia coli, Intestinal Mucosa, Lab-On-A-Chip Devices. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Taichung Veterans General Hospital, Collaborative Grants with National Yang Ming Chiao Tung University, National Science and Technology Council.
Abstract (Originalsprache)
The intestinal epithelium and its resident microbiota form a dynamic interface that is central to gut homeostasis, but this interface is difficult to model with conventional tools. Static Transwell cultures lack physiological fluid shear, whereas animal models are costly and poorly suited to quantitative, high‐content imaging. Organ‐on‐a‐chip technology offers a way to recreate key physical and biological features of the gut, yet many existing gut‐on‐chip systems remain technically demanding or poorly standardized for routine use. Here, we developed and validated a practical gut‐on‐chip workflow that enables reproducible, imaging‐based quantification of epithelial barrier dynamics during short‐term co‐culture with Escherichia coli . Using a commercial two‐channel microfluidic chip and Caco‐2 cells, we first established a perfused intestinal model under low‐flow conditions (0.5–1 µL/min) and confirmed long‐term stability by phase‐contrast imaging, LIVE/DEAD staining, and immunofluorescence for ZO‐1, F‐actin, and wheat germ agglutinin (WGA). This protocol generated a confluent, polarized monolayer with continuous tight junctions and an apical glycoprotein mucus layer. We then introduced HADA‐labeled E. coli and systematically varied the perfusion rate during co‐culture. At 0.5 µL/min, the epithelial layer, although stable in monoculture, underwent rapid thinning and focal detachment within 4 days of co‐culture, indicating that low shear is insufficient to buffer bacterial overgrowth and metabolite accumulation. In contrast, Caco‐2 monolayers tolerated perfusion up to 10 µL/min without structural damage, and at this higher flow rate we achieved a stable, 24‐h analytical window in which epithelial integrity and bacterial distribution could be imaged reliably. Structural disruption only became evident when co‐culture was extended to four and 7 days. Taken together, these results identify perfusion rate as the decisive parameter for stabilizing host–microbe co‐culture on a gut‐on‐chip platform. The workflow described here couples a functionally validated epithelial barrier with an experimentally simple, yet robust, perfusion regime. It provides an accessible test‐bed for quantitative studies of early host–microbe interactions and can be readily extended with orthogonal barrier readouts, such as TEER or tracer permeability, in future work.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Colorectal Surgery, Department of Surgery, Taichung Veterans General Hospital, Taichung, Taiwan.
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
- Institute of Intelligent Bioelectrical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
- Anivance AI Corporation, Zhubei City, Hsinchu County, Taiwan.
- Department of Biological Science and Technology, College of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
- Center for Intelligent Drug Systems and Smart Bio-devices (IDS2B), National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
ORCID-Profile: Shih-Wei Chiang, Guan-Yu Chen
Förderung
- Taichung Veterans General Hospital
- Collaborative Grants with National Yang Ming Chiao Tung University
- National Science and Technology Council
Zitieren
APA
Chiang, S. W., Yang, C. Y., & Chen, G. Y. (2026). A Practical Gut‐On‐Chip Workflow for Imaging‐Based Assessment of Epithelial Barrier Dynamics During E. coli Co‐Culture. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.70240
Vancouver
Chiang SW, Yang CY, Chen GY. A Practical Gut‐On‐Chip Workflow for Imaging‐Based Assessment of Epithelial Barrier Dynamics During E. coli Co‐Culture. Biotechnology and Bioengineering. 2026. doi:10.1002/bit.70240
BibTeX
@article{Chiang2026,
author = {Chiang, Shih-Wei and Yang, Chuan-Yi and Chen, Guan-Yu},
title = {A Practical Gut‐On‐Chip Workflow for Imaging‐Based Assessment of Epithelial Barrier Dynamics During E. coli Co‐Culture},
journal = {Biotechnology and Bioengineering},
year = {2026},
doi = {10.1002/bit.70240}
}
EUVIMED