Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy
Biotechnology and Bioengineering · 2025-12 · 122 (12) · 3339-3354
DOI: 10.1002/bit.70060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology and Bioengineering, online erschienen am 10.09.2025. Verfasst von Harshal Soni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA. Hauptthemen laut MEDLINE: Chromatography, Affinity, Dependovirus, Resins, Synthetic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: The authors acknowledge National Science Foundation (NSF-MRI-1725984) for supporting the confocal microscopy investigations carried out in this study..
Abstract (Originalsprache)
In this work, confocal microscopy is employed to study the loading and fouling behavior in AAV affinity resins as well as the implications of resin reuse with several commercial chromatographic materials and feed mixtures. Resin samples are obtained from both batch and column experiments, and confocal microscopy is carried out to examine the adsorption profiles in the beads after loading, wash, elution, and CIP steps. A comparison of PSDVB‐based POROS CaptureSelect (PCS) AAV resins with agarose‐based AVIPure AAV9 resins revealed distinct differences in both AAV transport and resin fouling. While AAVs were able to fully access the entire PCS AAV resin under loading onto virgin resin materials, they were restricted to the surface region of the AVIPure AAV9 resin. High resolution X‐ray CT scans indicate that the large pores of the PCS media are likely responsible for this enhanced transport. However, AAV transport into full PCS AAV resin volume was found to only occur during the first AAV loading experiment and was not observed when clarified lysate was employed or upon resin reuse. Further, confocal microscopy indicated that fouling of the PCS AAV affinity resins occurred due to deposition and carryover of AAV and residual impurities upon column re‐use, likely due to incomplete elution and ineffective column CIP. Interestingly, this residual binding in the region near the resin surface resulted in limiting solute transport in subsequent cycles, likely due to pore occlusion. In contrast, AAV bound to the AVIPure resin was readily eluted and removed during CIP. This study elucidates the impact of resin characteristics, feed constituents, and process conditions on the lifetime and fouling of AAV affinity columns.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA.
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, USA.
- Department of Biochemical Engineering, University College London, Bernard Katz, London, UK.
ORCID-Profile: Harshal Soni, Thomas F Johnson, Steven M Cramer
Förderung
- The authors acknowledge National Science Foundation (NSF-MRI-1725984) for supporting the confocal microscopy investigations carried out in this study.
Zitieren
APA
Soni, H., Pryshchep, S., Johnson, T. F., & Cramer, S. M. (2025). Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy. Biotechnology and Bioengineering, 122(12), 3339-3354. https://doi.org/10.1002/bit.70060
Vancouver
Soni H, Pryshchep S, Johnson TF, Cramer SM. Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy. Biotechnology and Bioengineering. 2025;122(12):3339-3354. doi:10.1002/bit.70060
BibTeX
@article{Soni2025,
author = {Soni, Harshal and Pryshchep, Sergey and Johnson, Thomas F and Cramer, Steven M},
title = {Elucidating the Interplay Between Resin Media, Feed Constituents, and Process Conditions in AAV Affinity Column Fouling With Confocal Microscopy},
journal = {Biotechnology and Bioengineering},
year = {2025},
volume = {122},
number = {12},
pages = {3339--3354},
doi = {10.1002/bit.70060}
}
EUVIMED