Computational fluid dynamics based digital twins of fixed bed bioreactors validate scaling principles for recombinant adeno‐associated virus gene therapy manufacturing
Biotechnology and Bioengineering · 2024-09 · 121 (9) · 2662-2677
DOI: 10.1002/bit.28727 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology and Bioengineering, online erschienen am 06.05.2024. Verfasst von Michael Hill und 5 weiteren Autor:innen. Beteiligte Einrichtung: Process Development, Passage Bio, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Dependovirus, Bioreactors, Hydrodynamics, Genetic Therapy. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Gene therapy using recombinant adeno‐associated virus (rAAV) as delivery vehicles has garnered much interest in recent years. There are still significant gaps in our fundamental understanding of the manufacturing processes to deliver sufficient products. Manufacturing efforts of rAAV using HEK293 cells have commonly relied on fixed bed falling film bioreactors like the iCELLis®. We used computational fluid dynamics (CFD) to validate the operating conditions required for a predictive iCELLis® 500 scale‐down model. The small‐scale and at‐scale systems have different flow paths causing validation of the corresponding agitation rates required to achieve the same linear flow through the fixed bed across scales to be non‐trivial. Therefore, we used CFD to predict the theoretical scaling relationship. In addition, CFD could predict kLa differences between the two systems and the operating conditions required to match kLa between scales. We also confirmed that the location of DO control must be the same in both systems to achieve proper scaling. Experimental runs confirming the validity of the novel scale‐down model showed that based on the modifications to the iCELLis® Nano system, we achieved similar DO, key metabolite, pH, and GC titer trends in both systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Process Development, Passage Bio, Philadelphia, Pennsylvania, USA.
- The Janssen Pharmaceutical Companies of Johnson & Johnson, Spring House, Philadelphia, Pennsylvania, USA.
- M-Star CFD, Ellicott City, Maryland, USA.
Zitieren
APA
Hill, M., White, C., Wang, S., Thomas, J., DeVincentis, B., & Singh, N. (2024). Computational fluid dynamics based digital twins of fixed bed bioreactors validate scaling principles for recombinant adeno‐associated virus gene therapy manufacturing. Biotechnology and Bioengineering, 121(9), 2662-2677. https://doi.org/10.1002/bit.28727
Vancouver
Hill M, White C, Wang S, Thomas J, DeVincentis B, Singh N. Computational fluid dynamics based digital twins of fixed bed bioreactors validate scaling principles for recombinant adeno‐associated virus gene therapy manufacturing. Biotechnology and Bioengineering. 2024;121(9):2662-2677. doi:10.1002/bit.28727
BibTeX
@article{Hill2024,
author = {Hill, Michael and White, Colten and Wang, Shaoying and Thomas, John and DeVincentis, Brian and Singh, Nripen},
title = {Computational fluid dynamics based digital twins of fixed bed bioreactors validate scaling principles for recombinant adeno‐associated virus gene therapy manufacturing},
journal = {Biotechnology and Bioengineering},
year = {2024},
volume = {121},
number = {9},
pages = {2662--2677},
doi = {10.1002/bit.28727}
}
EUVIMED