EUVIMEDEUVIMED entdecken
Crossref

Evaluation of various membranes at different fluxes to enable large‐volume single‐use perfusion bioreactors

Hassan Raza, Tiffany Tang, Baizhen Gao, Chelsea Phuangthong, Chienhung Billy Chen, Nuno D S Pinto

Biotechnology and Bioengineering · 2024

DOI: 10.1002/bit.28722 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology and Bioengineering, 2024. Verfasst von Hassan Raza und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biologics Process Research & Development, Merck & Co., Inc., Rahway, New Jersey, USA. Hauptthemen laut MEDLINE: Bioreactors, Membranes, Artificial, Antibodies, Monoclonal, Cricetulus. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The growing demand for biological therapeutics has increased interest in large‐volume perfusion bioreactors, but the operation and scalability of perfusion membranes remain a challenge. This study evaluates perfusion cell culture performance and monoclonal antibody (mAb) productivity at various membrane fluxes (1.5–5 LMH), utilizing polyvinylidene difluoride (PVDF), polyethersulfone (PES), or polysulfone (PS) membranes in tangential flow filtration mode. At low flux, culture with PVDF membrane maintained higher cell culture growth, permeate titer (1.06–1.34 g/L) and sieving coefficients (≥83%) but showed lower permeate volumetric throughput and higher transmembrane pressure (TMP) (>1.50 psi) in the later part of the run compared to cultures with PES and PS membrane. However, as permeate flux increased, the total mass of product decreased by around 30% for cultures with PVDF membrane, while it remained consistent with PES and PS membrane, and at the highest flux studied, PES membrane generated 12% more product than PVDF membrane. This highlights that membrane selection for large‐volume perfusion bioreactors depends on the productivity and permeate flux required. Since operating large‐volume perfusion bioreactors at low flux would require several cell retention devices and a complex setup, PVDF membranes are suitable for low‐volume operations at low fluxes whereas PES membranes can be a desirable alternative for large‐volume higher demand products at higher fluxes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BioreactorsMembranes, ArtificialAntibodies, MonoclonalCricetulusCHO CellsAnimalsCell Culture TechniquesPolymersSulfonesPerfusionPolyvinylsCricetinaeFluorocarbon Polymers

Stichwörter der Autor:innen

TFF‐based perfusion cell culturecontinuous manufacturingmembrane chemistrymembrane foulingmonoclonal antibody productivitypermeate flux

Substanzen

Membranes, ArtificialAntibodies, MonoclonalPolymersSulfonesPolyvinylspolyvinylidene fluoridepolyether sulfoneFluorocarbon Polymers

Autor:innen und Institutionen

  • Biologics Process Research & Development, Merck & Co., Inc., Rahway, New Jersey, USA.
  • Analytical Research & Development, Merck & Co., Inc., Rahway, New Jersey, USA.

Zitieren

APA

Raza, H., Tang, T., Gao, B., Phuangthong, C., Chen, C. B., & Pinto, N. D. S. (2024). Evaluation of various membranes at different fluxes to enable large‐volume single‐use perfusion bioreactors. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.28722

Vancouver

Raza H, Tang T, Gao B, Phuangthong C, Chen CB, Pinto NDS. Evaluation of various membranes at different fluxes to enable large‐volume single‐use perfusion bioreactors. Biotechnology and Bioengineering. 2024. doi:10.1002/bit.28722

BibTeX
@article{Raza2024,
  author = {Raza, Hassan and Tang, Tiffany and Gao, Baizhen and Phuangthong, Chelsea and Chen, Chienhung Billy and Pinto, Nuno D S},
  title = {Evaluation of various membranes at different fluxes to enable large‐volume single‐use perfusion bioreactors},
  journal = {Biotechnology and Bioengineering},
  year = {2024},
  doi = {10.1002/bit.28722}
}
Kostenlos starten →