Fachartikel in der Zeitschrift Biotechnology and Bioengineering, 2023. Verfasst von Mariana N São Pedro und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology, Delft University of Technology, Delft, The Netherlands. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Biological Products. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real‐time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision‐making. A fluorescent dye (FD)‐based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis‐ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real‐time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab‐scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at‐line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalBiological ProductsTechnology

Stichwörter der Autor:innen

antibody aggregationcontinuous biomanufacturingfluorescent dyesmicrofluidic sensorprocess analytical technology (PAT)

Substanzen

Antibodies, MonoclonalBiological Products

Autor:innen und Institutionen

  • Department of Biotechnology, Delft University of Technology, Delft, The Netherlands.
  • Department of Chemical Engineering, Lund University, Lund, Sweden.
  • Byondis B. V., Nijmegen, The Netherlands.
  • Bioprocessing Engineering, Wageningen University, Wageningen, The Netherlands.

ORCID-Profile: Mariana N São Pedro, Bernt Nilsson

Zitieren

APA

São Pedro, M. N., Isaksson, M., Gomis-Fons, J., Eppink, M. H. M., Nilsson, B., & Ottens, M. (2023). Real‐time detection of mAb aggregates in an integrated downstream process. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.28466

Vancouver

São Pedro MN, Isaksson M, Gomis-Fons J, Eppink MHM, Nilsson B, Ottens M. Real‐time detection of mAb aggregates in an integrated downstream process. Biotechnology and Bioengineering. 2023. doi:10.1002/bit.28466

BibTeX
@article{SoPedro2023,
  author = {São Pedro, Mariana N and Isaksson, Madelène and Gomis-Fons, Joaquín and Eppink, Michel H M and Nilsson, Bernt and Ottens, Marcel},
  title = {Real‐time detection of mAb aggregates in an integrated downstream process},
  journal = {Biotechnology and Bioengineering},
  year = {2023},
  doi = {10.1002/bit.28466}
}
Kostenlos starten →