EUVIMEDEUVIMED entdecken
Open Access

Dual‐Similarity Driven Just‐in‐Time Modeling Enables Precise Real‐Time Monitoring of Cell Cultures via Dielectric Spectroscopy

Dongliang Chen, Qiongqiong Zhang, Zhe Lang iD, Zheyu Wang, Xiang Zheng iD, Mingyue Fang, Hang Zhou iD

Biotechnology Journal · 2026-05 · 21 (5)

DOI: 10.1002/biot.70235 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology Journal, online erschienen am 12.05.2026. Verfasst von Dongliang Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Cell Culture Process Development (CCPD), WuXi Biologics, Waigaoqiao Free Trade Zone, Shanghai, China. Hauptthemen laut MEDLINE: Dielectric Spectroscopy, Cell Culture Techniques. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biopharmaceutical industry is increasingly focused on shortening development timelines to accelerate progression into clinical stages, thereby improving patient outcomes and boosting market competitiveness. Dielectric spectroscopy, a promising process analytical technology (PAT), offers enhanced monitoring, and control of mammalian cell culture bioprocesses, but its practical application is constrained by the limited accuracy of existing models due to sparse historical data within compressed development periods. Just‐in‐time modeling (JITM) has recently emerged as a soft sensing approach balancing model accuracy and generalizability. However, its application in dielectric spectroscopy remains unreported, mainly due to the absence of suitable similarity metrics. This study firstly proposes a novel dual‐similarity driven JITM framework tailored for dielectric spectroscopy‐based modeling. Various similarity strategies were evaluated through validation study, then the generalizability of JITM was demonstrated using multiple local model algorithms, while its effectiveness was further confirmed using a testing application involving real‐time predictions of VCD. Compared to traditional techniques, the proposed JITM framework exhibited reliable and accurate VCD monitoring across diverse cell lines and culture conditions, showing great potential for industrial applications, especially in agile biomanufacturing where historical data and development time are limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dielectric SpectroscopyCell Culture TechniquesAnimalsAlgorithmsCricetulusCHO CellsModels, Biological

Stichwörter der Autor:innen

biomassdielectric spectroscopyjust‐in‐timeprocess analytical technologysoft sensing

Autor:innen und Institutionen

  • Cell Culture Process Development (CCPD), WuXi Biologics, Waigaoqiao Free Trade Zone, Shanghai, China.
  • Non-GMP Pilot Plant (NPP), WuXi Biologics, Waigaoqiao Free Trade Zone, Shanghai, China.
  • Bioprocess Research and Development (BRD), WuXi Biologics, Waigaoqiao Free Trade Zone, Shanghai, China.

ORCID-Profile: Zhe Lang, Xiang Zheng, Hang Zhou

Zitieren

APA

Chen, D., Zhang, Q., Lang, Z., Wang, Z., Zheng, X., Fang, M., & Zhou, H. (2026). Dual‐Similarity Driven Just‐in‐Time Modeling Enables Precise Real‐Time Monitoring of Cell Cultures via Dielectric Spectroscopy. Biotechnology Journal, 21(5). https://doi.org/10.1002/biot.70235

Vancouver

Chen D, Zhang Q, Lang Z, Wang Z, Zheng X, Fang M, et al. Dual‐Similarity Driven Just‐in‐Time Modeling Enables Precise Real‐Time Monitoring of Cell Cultures via Dielectric Spectroscopy. Biotechnology Journal. 2026;21(5). doi:10.1002/biot.70235

BibTeX
@article{Chen2026,
  author = {Chen, Dongliang and Zhang, Qiongqiong and Lang, Zhe and Wang, Zheyu and Zheng, Xiang and Fang, Mingyue and Zhou, Hang},
  title = {Dual‐Similarity Driven Just‐in‐Time Modeling Enables Precise Real‐Time Monitoring of Cell Cultures via Dielectric Spectroscopy},
  journal = {Biotechnology Journal},
  year = {2026},
  volume = {21},
  number = {5},
  doi = {10.1002/biot.70235}
}
Kostenlos starten →