Novel Approach Using Real‐Time Dynamic Imaging Analysis to Monitor Cellular Apoptosis, Viability, and Cell Density in CHO Cell‐Based Bioprocesses for Monoclonal Antibody Production
Biotechnology Journal · 2025
DOI: 10.1002/biot.70018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology Journal, 2025. Verfasst von Claudia Corredor und 4 weiteren Autor:innen. Beteiligte Einrichtung: Integrated Technologies and Engineering, Drug Product Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA. Hauptthemen laut MEDLINE: Apoptosis, Antibodies, Monoclonal, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
We investigated an analytical method based on dynamic imaging analysis (DIA) for monitoring cellular apoptosis, viability, and cell density. Trypan blue and flow cytometry were used as reference methods. The DIA method showed results comparable to the traditional methods, with clear advantages (label‐free and in‐line real‐time monitoring capability). The DIA method successfully traced the trajectory of cell death progress, detecting the onset of apoptosis earlier than the other methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Integrated Technologies and Engineering, Drug Product Development, Bristol-Myers Squibb, New Brunswick, New Jersey, USA.
- Biologics Process Analytics, Biologics Development, Bristol-Myers Squibb, Devens, Massachusetts, USA.
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania, USA.
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania, USA.
ORCID-Profile: Claudia Corredor, Suyang Wu
Zitieren
APA
Corredor, C., Zhao, Y., Wu, S., Drennen, J. K., & Anderson, C. (2025). Novel Approach Using Real‐Time Dynamic Imaging Analysis to Monitor Cellular Apoptosis, Viability, and Cell Density in CHO Cell‐Based Bioprocesses for Monoclonal Antibody Production. Biotechnology Journal. https://doi.org/10.1002/biot.70018
Vancouver
Corredor C, Zhao Y, Wu S, Drennen JK, Anderson C. Novel Approach Using Real‐Time Dynamic Imaging Analysis to Monitor Cellular Apoptosis, Viability, and Cell Density in CHO Cell‐Based Bioprocesses for Monoclonal Antibody Production. Biotechnology Journal. 2025. doi:10.1002/biot.70018
BibTeX
@article{Corredor2025,
author = {Corredor, Claudia and Zhao, Yuxiang and Wu, Suyang and Drennen, James K and Anderson, Carl},
title = {Novel Approach Using Real‐Time Dynamic Imaging Analysis to Monitor Cellular Apoptosis, Viability, and Cell Density in CHO Cell‐Based Bioprocesses for Monoclonal Antibody Production},
journal = {Biotechnology Journal},
year = {2025},
doi = {10.1002/biot.70018}
}
EUVIMED