Facile prepared microfluidic chip for multiplexed digital RT‐qPCR test
Biotechnology Journal · 2024
DOI: 10.1002/biot.202300273 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology Journal, 2024. Verfasst von Wenqi Hu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, Jiangsu, P. R. China. Hauptthemen laut MEDLINE: Nucleic Acids, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jiangsu Specially-Appointed Professor, Excellent Youth Foundation of Jiangsu Scientific Committee.
Abstract (Originalsprache)
The chip‐based digital polymerase chain reaction (PCR) is an indispensable technique for amplifying and quantifying nucleic acids, which has been widely employed in molecular diagnostics at both fundamental and clinical levels. However, the previous designs have yet to achieve widespread application due to limitations in complex chip fabrication, pretreatment procedures, special surface properties, and low throughput. This study presents a facile digital microfluidic chip driven by centrifugal force for digital PCR analysis. Interestingly, regardless of the hydrophilicity or hydrophobicity of the inner chip surface, an efficient digitization process can be achieved. PCR reagents introduced into the inlet can be allocated to 9600 microchambers and subsequently isolated by the immiscible phase (silicone oil). The centrifugal priming approach offers a facile means to achieve high‐throughput analysis. The design was further employed for the quantification of nucleic acids using digital PCR. The calculated result exhibited a strong correlation with the measured value at the concentrations from 1 copy/μL to 1000 copies/μL ( R 2 = 0.99). Additionally, the chip also allowed digital multiplexed analysis, thereby indicating its potential for multi‐target detection applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, Jiangsu, P. R. China.
- Medical School of Nantong University, Nantong University, Nantong, Jiangsu, P. R. China.
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu, P. R. China.
- Nantong Center for Disease Control and Prevention, Nantong, Jiangsu, P. R. China.
- Nantong Egens Biotechnology Co., Ltd, Nantong, Jiangsu, P. R. China.
- Department of Blood Transfusion, Affiliated Hospital of Nantong University, Nantong, Jiangsu, P. R. China.
ORCID-Profile: Yuling Qin
Förderung
- National Natural Science Foundation of China
- Jiangsu Specially-Appointed Professor
- Excellent Youth Foundation of Jiangsu Scientific Committee
- Jiangsu Innovative and Entrepreneurial Research Team Program
- Large Instruments Open Foundation of Nantong University
Zitieren
APA
Hu, W., Zhu, Y., Tang, Q., Ji, X., Wang, L., Ou, W., Li, G., Wu, L., Cong, H., & Qin, Y. (2024). Facile prepared microfluidic chip for multiplexed digital RT‐qPCR test. Biotechnology Journal. https://doi.org/10.1002/biot.202300273
Vancouver
Hu W, Zhu Y, Tang Q, Ji X, Wang L, Ou W, et al. Facile prepared microfluidic chip for multiplexed digital RT‐qPCR test. Biotechnology Journal. 2024. doi:10.1002/biot.202300273
BibTeX
@article{Hu2024,
author = {Hu, Wenqi and Zhu, Yidan and Tang, Qu and Ji, Xiaolei and Wang, Lei and Ou, Weijun and Li, Guo and Wu, Li and Cong, Hui and Qin, Yuling},
title = {Facile prepared microfluidic chip for multiplexed digital RT‐qPCR test},
journal = {Biotechnology Journal},
year = {2024},
doi = {10.1002/biot.202300273}
}
EUVIMED