Fachartikel in der Zeitschrift Luminescence, 2026. Verfasst von Gopal Kumar Mahato und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Physical and Chemical Sciences, Central University of South Bihar, Gaya, Bihar, India. Hauptthemen laut MEDLINE: Mercury, Fluorescent Dyes, Iron. Die Arbeit nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Here, we report the design and synthesis of a new bicyclic compound 6 , annulated with benzene and the 8‐hydroxyquinoline fluorophore. The probe exhibits a moderate aggregation‐induced emission (AIE) behavior upon the addition of water up to 17%. Furthermore, the probe exhibits a highly selective fluorescence turn‐off response toward Fe 3+ and Hg 2+ ions in a DMSO/H 2 O (83:17, v/v) solution over a range of other competitive metal ions. The probe displayed low detection limits of 3.69 μM for Fe 3+ and 6.08 μM Hg 2+ . Probe 6 shows a fast recognition time of ions and can monitor Fe 3+ and Hg 2+ ions in real time. The sensing mechanism is thoroughly investigated by time‐dependent 1 H NMR studies, which indicate coordination interactions between the quinoline framework and the metal ions. The probe demonstrates high sensitivity and dual‐selectivity toward metal ion sensing, making it a valuable tool for monitoring the environment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MercuryFluorescent DyesIronWaterSpectrometry, FluorescenceFluorescenceSolutionsFluorescent Chemosensor CompoundsMolecular StructureOxyquinoline

Stichwörter der Autor:innen

8‐hydroxy quinolineaggregation‐induced emissionfluorescence emissionmetal sensingspiroepoxy‐bicyclo [2.2.2] octane

Substanzen

MercuryFluorescent DyesWaterIronSolutionsFluorescent Chemosensor CompoundsOxyquinoline

Autor:innen und Institutionen

  • Department of Chemistry, School of Physical and Chemical Sciences, Central University of South Bihar, Gaya, Bihar, India.
  • Department of Bioinformatics, School of Earth, Biological and Environmental Sciences, Central University of South Bihar, Gaya, Bihar, India.

ORCID-Profile: Gopal Kumar Mahato, Durg Vijay Singh, Girish Chandra

Zitieren

APA

Mahato, G. K., Singh, D. V., & Chandra, G. (2026). Design and Synthesis of Dual Fluorophore for Detection of Fe 3+ and Hg 2+ in Aqueous Solution Through Fluorescence “Turn‐Off”. Luminescence. https://doi.org/10.1002/bio.70648

Vancouver

Mahato GK, Singh DV, Chandra G. Design and Synthesis of Dual Fluorophore for Detection of Fe 3+ and Hg 2+ in Aqueous Solution Through Fluorescence “Turn‐Off”. Luminescence. 2026. doi:10.1002/bio.70648

BibTeX
@article{Mahato2026,
  author = {Mahato, Gopal Kumar and Singh, Durg Vijay and Chandra, Girish},
  title = {Design and Synthesis of Dual Fluorophore for Detection of Fe 3+ and Hg 2+ in Aqueous Solution Through Fluorescence “Turn‐Off”},
  journal = {Luminescence},
  year = {2026},
  doi = {10.1002/bio.70648}
}
Kostenlos starten →