EUVIMEDEUVIMED entdecken
Crossref

Smartphone‐Assisted Chemiluminescence System to Detect Fe in Drinking Water Samples

Ajit Singh Bhurgy iD, Purshottam J Assudani

Luminescence · 2026-06 · 41 (6)

DOI: 10.1002/bio.70529 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, online erschienen am 05.06.2026. Verfasst von Ajit Singh Bhurgy und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science and Engineering, Ramdeobaba University, Nagpur, Maharashtra, India. Hauptthemen laut MEDLINE: Smartphone, Drinking Water, Iron, Luminescent Measurements. Die Arbeit nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Iron (Fe) contamination in drinking water poses significant health risks, including organ damage and oxidative stress, emphasizing the need for rapid and portable detection methods. This study presents a novel chemiluminescence (CL)‐based approach integrated with smartphone imaging for quantitative detection of Fe in drinking water samples. A luminol‐hydrogen peroxide system, catalyzed by Fe, was optimized to achieve sensitive calibration, yielding a detection limit of 0.675 μM and a limit of quantification of 2.25 μM across a working range of 1–50 μM. The methodology was systematically validated through repeatability, reproducibility, and interference analysis. Real‐world applicability was demonstrated by analyzing three different tap water samples using a recovery‐based approach. This work also highlights the potential of coupling CL with smartphones, offering a low‐cost, user‐friendly, and scalable solution for environmental monitoring. The proposed protocol can be a viable alternative to conventional laboratory‐based methods and pave the way for real‐time water quality monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneDrinking WaterIronLuminescent MeasurementsWater Pollutants, ChemicalLuminescenceHydrogen PeroxideLuminol

Stichwörter der Autor:innen

chemiluminescence (CL)drinking water samplesiron (Fe) contaminationpoint of source testing (PoST)smartphone detection

Substanzen

Drinking WaterIronHydrogen PeroxideWater Pollutants, ChemicalLuminol

Autor:innen und Institutionen

  • School of Computer Science and Engineering, Ramdeobaba University, Nagpur, Maharashtra, India.

ORCID-Profile: Ajit Singh Bhurgy

Zitieren

APA

Bhurgy, A. S., & Assudani, P. J. (2026). Smartphone‐Assisted Chemiluminescence System to Detect Fe in Drinking Water Samples. Luminescence, 41(6). https://doi.org/10.1002/bio.70529

Vancouver

Bhurgy AS, Assudani PJ. Smartphone‐Assisted Chemiluminescence System to Detect Fe in Drinking Water Samples. Luminescence. 2026;41(6). doi:10.1002/bio.70529

BibTeX
@article{Bhurgy2026,
  author = {Bhurgy, Ajit Singh and Assudani, Purshottam J},
  title = {Smartphone‐Assisted Chemiluminescence System to Detect Fe in Drinking Water Samples},
  journal = {Luminescence},
  year = {2026},
  volume = {41},
  number = {6},
  doi = {10.1002/bio.70529}
}