EUVIMEDEUVIMED entdecken
Crossref

A Turn‐On Fluorescent Chemical Sensor Based on Benzo[f]Chromen Structure for Cu 2+ ‐Sensitive Detection as Well as Applications

Qian Sun, Lu Ren, Shuangbao Li iD, Zian Wang, Jing Liu, Zhaoyun Yang, Dawei Zhang iD

Luminescence · 2026-03 · 41 (3)

DOI: 10.1002/bio.70466 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, online erschienen am 14.03.2026. Verfasst von Qian Sun und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Pharmaceutical Engineering, Jilin University of Chemical Technology, Jilin City, China. Hauptthemen laut MEDLINE: Copper, Fluorescent Dyes, Benzopyrans. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple Schiff base probe ( E )‐ N′ ‐(1‐(3‐oxo‐3 H ‐benzo[f]chromen‐2‐yl)ethylidene) picolinohydrazide (CHH) was synthesized and characterized by Fourier transform infrared spectroscopy (FT‐IR), 1 H nuclear magnetic resonance spectra ( 1 H NMR), 13 C nuclear magnetic resonance spectra ( 13 C NMR), and high‐resolution mass spectrometry (HR‐MS). The probe CHH shows high sensitivity and selectivity for the recognition of Cu 2+ in EtOH‐H 2 O (1:1, v/v), and exhibits an enhanced fluorescence phenomenon. The binding constant of CHH for Cu 2+ is 2.74 × 10 5 M −1 , and the binding stoichiometry of CHH and Cu 2+ is 1:1. The fluorescence intensity of CHH (10 μM) is well linearized with the Cu 2+ concentration at 0–10 μM, and it has a detection limit of 1.42 nM, which is lower than the detection limits of most similar probes. The reusability of the probe was evaluated by successively adding Cu 2+ and disodium ethylenediaminetetraacetate (Na 2 EDTA) to the CHH solution. The probe CHH was used to quantitatively detect Cu 2+ in actual water samples from different water sources. The recovery rates were within an acceptable range, indicating that the probe CHH can be used for the quantitative detection of Cu 2+ in actual water samples. Furthermore, the probe was applied for fingerprint detection, showing great potential in fingerprint detection and anti‐counterfeiting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperFluorescent DyesBenzopyransSpectrometry, FluorescenceMolecular StructureFluorescent Chemosensor CompoundsSchiff BasesLimit of DetectionFluorescence

Stichwörter der Autor:innen

copper (II)coumarinfingerprintfluorescent sensorswater samples

Substanzen

CopperFluorescent DyesFluorescent Chemosensor CompoundsBenzopyransSchiff Bases

Autor:innen und Institutionen

  • College of Chemistry and Pharmaceutical Engineering, Jilin University of Chemical Technology, Jilin City, China.

ORCID-Profile: Shuangbao Li, Dawei Zhang

Zitieren

APA

Sun, Q., Ren, L., Li, S., Wang, Z., Liu, J., Yang, Z., & Zhang, D. (2026). A Turn‐On Fluorescent Chemical Sensor Based on Benzo[f]Chromen Structure for Cu 2+ ‐Sensitive Detection as Well as Applications. Luminescence, 41(3). https://doi.org/10.1002/bio.70466

Vancouver

Sun Q, Ren L, Li S, Wang Z, Liu J, Yang Z, et al. A Turn‐On Fluorescent Chemical Sensor Based on Benzo[f]Chromen Structure for Cu 2+ ‐Sensitive Detection as Well as Applications. Luminescence. 2026;41(3). doi:10.1002/bio.70466

BibTeX
@article{Sun2026,
  author = {Sun, Qian and Ren, Lu and Li, Shuangbao and Wang, Zian and Liu, Jing and Yang, Zhaoyun and Zhang, Dawei},
  title = {A Turn‐On Fluorescent Chemical Sensor Based on Benzo[f]Chromen Structure for Cu 2+ ‐Sensitive Detection as Well as Applications},
  journal = {Luminescence},
  year = {2026},
  volume = {41},
  number = {3},
  doi = {10.1002/bio.70466}
}
Kostenlos starten →