Cysteine‐Mediated N, S‐Graphene Quantum Dots Adorned UiO‐MOFs Nanocomposite: A Fast and Ultrasensitive Fluorescence Sensor for Para‐Amino Hippuric Acid
Luminescence · 2025
DOI: 10.1002/bio.70211 ↗Kurz gefasst
Fachartikel in der Zeitschrift Luminescence, 2025. Verfasst von Shoheb S Manyar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, Maharashtra, India. Hauptthemen laut MEDLINE: Quantum Dots, Graphite, Cysteine, Nanocomposites. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 72 Literaturangaben.
Abstract (Originalsprache)
Estimating para‐aminohippuric acid (PAH) as a potential bioindicator for diagnosing renal diseases is gaining prominence. Hence, this study aims to develop a novel nanoprobe using cysteine‐mediated N, S‐graphene quantum dots (N, S‐GQDs) embedded in UiO metal–organic frameworks (N, S‐GQDs@UiO‐MOFs) for PAH monitoring. Simultaneous green synthesis and doping of GQDs were initially done using Alstonia scholaris leaves and L‐cysteine via the one‐pot hydrothermal method to enhance their selectivity and optical properties. Fluorescent UiO‐MOFs were then synthesized by 2‐aminoterephthalic acid (2‐ATA) and zirconium tetrachloride (ZrCl 4 ) providing a large surface area suitable for decorating N, S‐GQDs. Adding copper ions (Cu II) results in FL quenching (turn‐off) to the probe solution. In contrast, PAH addition led to FL recovery (turn‐on), attributed to interaction with the amino functionality of PAH and the formation of a Cu (II)‐PAH complex. The developed sensor exhibited a broad dynamic range (3 –17 ng mL −1 ), an impressive detection limit (LOD: 662 pg mL −1 ), and a quantification limit (LOQ: 2 ng mL −1 ). Validation in artificial urine confirmed the sensor's specificity and suitability for real‐time PAH analysis, demonstrating good stability, repeatability, and selectivity. The integrated N, S‐GQDs@UiO‐MOFs nanoprobe shows promise as a preferred method for PAH detection in clinical samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmaceutical Chemistry, H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, Maharashtra, India.
ORCID-Profile: Shoheb S Manyar, Sopan Nangare
Zitieren
APA
Manyar, S. S., Nangare, S., Mahajan, M. R., Khatik, Z. K. A., & Patil, P. O. (2025). Cysteine‐Mediated N, S‐Graphene Quantum Dots Adorned UiO‐MOFs Nanocomposite: A Fast and Ultrasensitive Fluorescence Sensor for Para‐Amino Hippuric Acid. Luminescence. https://doi.org/10.1002/bio.70211
Vancouver
Manyar SS, Nangare S, Mahajan MR, Khatik ZKA, Patil PO. Cysteine‐Mediated N, S‐Graphene Quantum Dots Adorned UiO‐MOFs Nanocomposite: A Fast and Ultrasensitive Fluorescence Sensor for Para‐Amino Hippuric Acid. Luminescence. 2025. doi:10.1002/bio.70211
BibTeX
@article{Manyar2025,
author = {Manyar, Shoheb S and Nangare, Sopan and Mahajan, Mahendra R and Khatik, Zabiullah K A and Patil, Pravin O},
title = {Cysteine‐Mediated N, S‐Graphene Quantum Dots Adorned UiO‐MOFs Nanocomposite: A Fast and Ultrasensitive Fluorescence Sensor for Para‐Amino Hippuric Acid},
journal = {Luminescence},
year = {2025},
doi = {10.1002/bio.70211}
}
EUVIMED