Development of 5,5′‐Bi(1,10‐Phenanthroline)‐Based PVC Membrane Potentiometric Sensor for Silver Determination
Luminescence · 2025
DOI: 10.1002/bio.70136 ↗Kurz gefasst
Fachartikel in der Zeitschrift Luminescence, 2025. Verfasst von Derya Güngördü Solğun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Yuzuncu Yıl University, Van, Türkiye. Hauptthemen laut MEDLINE: Silver, Phenanthrolines, Polyvinyl Chloride, Membranes, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
In this study, the selectivity of the 5.5′‐bi(1,10‐phenanthroline) Compound ( 1 ) against Ag + ions as a chemical sensor was investigated by both absorption and potentiometric methods. First, a 1 × 10 −5 M solution of Compound ( 1 ) in acetonitrile was prepared. For the selectivity test, 1 × 10 −2 M solutions of metal ions in acetonitrile were prepared. UV–visible absorption measurements were performed by adding metal ions to a 5.5′‐bi(1,10‐phenanthroline) compound at certain concentrations. Among the studied metal ions, it was found to be selective only against silver ions. In addition, solid‐state contact polyvinylchloride (PVC) membrane electrodes prepared using 5.5′‐bi(1,10‐phenanthroline) as an ionophore were found to be selective against Ag + ions among other ions. The optimum membrane composition of the measurement was determined as 3% 5.5′‐bi(1,10‐phenanthroline) + 32% PVC + 64% o‐nitrophenyl octyl ether (o‐NPOE) + 1% potassium tetrakis(4‐chlorophenyl) borate (KTpClPB). The potentiometric properties of the silver selective electrode were determined as linear working range 1.0 × 10 −7 –1.0 × 10 −3 M, detection limit 1.0 × 10 −7 M, pH working range 3.23–9.08, and response time 3 s. Absorption and potentiometric methods confirm the selectivity towards silver ions. The IRC analysis of the silver‐containing complex, performed using the DFT/B3LYP method with the LanL2DZ basis set, reveals an activation energy of approximately 0.002 Eh, with the transition state energy at −1.433173 Eh.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Science, Yuzuncu Yıl University, Van, Türkiye.
ORCID-Profile: Mehmet Salih Ağirtaş
Zitieren
APA
Güngördü Solğun, D., Kaya, N., Saydan Kanberoğlu, G., & Ağirtaş, M. S. (2025). Development of 5,5′‐Bi(1,10‐Phenanthroline)‐Based PVC Membrane Potentiometric Sensor for Silver Determination. Luminescence. https://doi.org/10.1002/bio.70136
Vancouver
Güngördü Solğun D, Kaya N, Saydan Kanberoğlu G, Ağirtaş MS. Development of 5,5′‐Bi(1,10‐Phenanthroline)‐Based PVC Membrane Potentiometric Sensor for Silver Determination. Luminescence. 2025. doi:10.1002/bio.70136
BibTeX
@article{GngrdSolun2025,
author = {Güngördü Solğun, Derya and Kaya, Nurcan and Saydan Kanberoğlu, Gülşah and Ağirtaş, Mehmet Salih},
title = {Development of 5,5′‐Bi(1,10‐Phenanthroline)‐Based PVC Membrane Potentiometric Sensor for Silver Determination},
journal = {Luminescence},
year = {2025},
doi = {10.1002/bio.70136}
}
EUVIMED