The FRET‐Based APTA Sensor/Cy3 Complex for Glucose Determination
Luminescence · 2025-02 · 40 (2)
DOI: 10.1002/bio.70097 ↗Kurz gefasst
Fachartikel in der Zeitschrift Luminescence, online erschienen am 06.02.2025. Verfasst von Ghasem Rezanejade Bardajee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Polymer and Materials Chemistry, Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, Tehran, Iran. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Fluorescent Dyes, Carbocyanines, Aptamers, Nucleotide. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Payame Noor University, SBU, Shahid Beheshti University.
Abstract (Originalsprache)
This study developed a sensitive and cost‐effective fluorescent probe based on the Förster Resonance Energy Transfer (FRET) method to monitor blood glucose levels. The APTA sensor/Cy3 probe consisted of cadmium telluride quantum dots modified with thioglycolic acid (CdTe‐TGA QDs), a thiol‐glucose‐aptamer, and a Cy3‐labeled aptamer. Due to the well‐matched emission spectrum of the CdTe QDs and the absorption spectrum of Cy3, the FRET system decreased fluorescence intensity. However, glucose molecules quenched it when introduced to the system. The linear relationship between fluorescence intensity and glucose concentration was established with a detection limit of 7.72 × 10 −9 M. The APTA sensor/Cy3 complex demonstrated excellent selectivity and specificity toward glucose and a high recovery rate of 96.00–101.11% in human serum and urine using the spiking method. The structural and morphological characteristics of the APTA sensor/Cy3 complex were confirmed by UV–visible spectroscopy, Fourier‐transform infrared spectroscopy (FT‐IR), X‐ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), energy dispersive X‐ray spectroscopy (EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), and dynamic light scattering (DLS) analyses. The results suggest that the FRET‐based APTA sensor/Cy3 complex would lead to the development of fluorescent probes for screening biological metabolites in clinical diagnostics and research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Polymer and Materials Chemistry, Faculty of Chemistry and Petroleum Sciences, Shahid Beheshti University, Tehran, Iran.
- Department of Chemistry, Payame Noor University, Tehran, Iran.
ORCID-Profile: Ghasem Rezanejade Bardajee, Afsaneh Rahimi Chahrogh, Mojdeh Atashkadi
Förderung
- Payame Noor University
- SBU
- Shahid Beheshti University
Zitieren
APA
Bardajee, G. R., Chahrogh, A. R., & Atashkadi, M. (2025). The FRET‐Based APTA Sensor/Cy3 Complex for Glucose Determination. Luminescence, 40(2). https://doi.org/10.1002/bio.70097
Vancouver
Bardajee GR, Chahrogh AR, Atashkadi M. The FRET‐Based APTA Sensor/Cy3 Complex for Glucose Determination. Luminescence. 2025;40(2). doi:10.1002/bio.70097
BibTeX
@article{Bardajee2025,
author = {Bardajee, Ghasem Rezanejade and Chahrogh, Afsaneh Rahimi and Atashkadi, Mojdeh},
title = {The FRET‐Based APTA Sensor/Cy3 Complex for Glucose Determination},
journal = {Luminescence},
year = {2025},
volume = {40},
number = {2},
doi = {10.1002/bio.70097}
}
EUVIMED