EUVIMEDEUVIMED entdecken
Crossref

A perovskite‐based electrochemiluminescence aptasensor for tetracycline screening

Yuxin Chen, Xinyi Zhong, Qiling Yang, Huiping Chen, Nan Hao, Shanwen Hu

Luminescence · 2024

DOI: 10.1002/bio.4717 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2024. Verfasst von Yuxin Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Inspection and Quarantine, School of Public Health, Fujian Medical University, Fuzhou, Fujian, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal Nanoparticles, Aptamers, Nucleotide, Oxides. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Joint Funds for the Innovation of Science and Technology, Fujian Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tetracyclines are currently the most commonly used class of antibiotics, and their residue issue significantly impacts public health safety. In this study, a surface modification of perovskite with cetyltrimethylammonium bromide led to the generation of stable electrochemiluminescence (ECL) emitters in aqueous systems and improved the biocompatibility of perovskite. A perovskite quantum dot‐based ECL sensing strategy was developed. Utilizing the corresponding aptamer of the antibiotics, strain displacement reactions were triggered, disrupting the ECL quenching system composed of perovskite and Ag nanoclusters (Ag NCs) on the electrode surface, generating a signal to achieve quantitative detection of several common tetracycline antibiotics. The perovskite quantum dot provided a strong and stable initial signal, while the efficient catalytic activity of the silver cluster enhanced the recognition sensitivity. Tetracycline, chlortetracycline, and oxytetracycline were used as examples to demonstrate the differentiation and quantitative detection through this method. In addition, the aptasensor exhibited analytical performance with the linear range (0.1–10 μM OTC) and good recovery rates of 94.7% to 101.6% in real samples. This approach has the potential to become a sensitive and practical approach for assessing antibiotic residues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMetal NanoparticlesAptamers, NucleotideOxidesTitaniumCalcium CompoundsTetracyclineElectrochemical TechniquesLuminescent MeasurementsAnti-Bacterial AgentsTetracyclines

Stichwörter der Autor:innen

electrochemiluminescenceperovskitetetracyclines

Substanzen

perovskiteTetracyclineAnti-Bacterial AgentsTetracyclinesAptamers, NucleotideOxidesTitaniumCalcium Compounds

Autor:innen und Institutionen

  • Department of Health Inspection and Quarantine, School of Public Health, Fujian Medical University, Fuzhou, Fujian, China.
  • School of Chemistry and Materials Science, Nanjing University of Information Science & Technology, Nanjing, China.

Förderung

  • Joint Funds for the Innovation of Science and Technology, Fujian Province

Zitieren

APA

Chen, Y., Zhong, X., Yang, Q., Chen, H., Hao, N., & Hu, S. (2024). A perovskite‐based electrochemiluminescence aptasensor for tetracycline screening. Luminescence. https://doi.org/10.1002/bio.4717

Vancouver

Chen Y, Zhong X, Yang Q, Chen H, Hao N, Hu S. A perovskite‐based electrochemiluminescence aptasensor for tetracycline screening. Luminescence. 2024. doi:10.1002/bio.4717

BibTeX
@article{Chen2024,
  author = {Chen, Yuxin and Zhong, Xinyi and Yang, Qiling and Chen, Huiping and Hao, Nan and Hu, Shanwen},
  title = {A perovskite‐based electrochemiluminescence aptasensor for tetracycline screening},
  journal = {Luminescence},
  year = {2024},
  doi = {10.1002/bio.4717}
}
Kostenlos starten →