EUVIMEDEUVIMED entdecken
Crossref

Structure‐switching aptasensors for sensitive detection of ochratoxin A

Yao-Yao Fan, Jie Wen, Jun Li, Xiao-Wen Yang, Lu Zhang, Zhi-Qi Zhang iD

Luminescence · 2023-09 · 38 (9) · 1678-1685

DOI: 10.1002/bio.4556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, online erschienen am 28.07.2023. Verfasst von Yao-Yao Fan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University,…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Ochratoxins, G-Quadruplexes, Biosensing Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ochratoxin A (OTA) is a toxic metabolite commonly found in various foods and feedstuffs. Accurate and sensitive detection of OTA is needed for food safety and human health. Based on a common OTA‐binding aptamer (OTABA), two structure‐switching OTABAs, namely OTABA4 and OTABA3, were designed by configuring a split G‐quadruplex and a split G‐triplex, respectively, at the two ends of OTABA to construct aptasensors for the detection of OTA. The OTABA, G‐quadruplex, and G‐triplex all can capture the thioflavin T (ThT) probe, thereby enhancing the fluorescence intensity of ThT. Bonding with OTA could change the conformations of OTABA and G‐quadruplex or G‐triplex regions, resulting in the release of the captured ThT and diminution of its fluorescence intensity. Dual conformation changes in structure‐switching OTABA synergistically amplified the fluorescence signal and improved the sensitivity of the aptasensor, especially for that with OTABA3. The detection limits of the OTABA4‐ThT and OTABA3‐ThT systems for OTA were 0.28 and 0.059 ng ml −1 , with a 1.4‐fold and 6.7‐fold higher sensitivity than that of the original OTABA‐ThT system, respectively. They performed well in corn and peanut samples and met the requirements of the food safety inspections.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideOchratoxinsG-QuadruplexesBiosensing TechniquesHumansFood ContaminationLimit of Detection

Stichwörter der Autor:innen

G-triplexaptasensorfluorescenceochratoxin Astructure-switching aptamer

Substanzen

ochratoxin AAptamers, NucleotideOchratoxins

Autor:innen und Institutionen

  • Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, China.

ORCID-Profile: Zhi-Qi Zhang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Fan, Y. Y., Wen, J., Li, J., Yang, X. W., Zhang, L., & Zhang, Z. Q. (2023). Structure‐switching aptasensors for sensitive detection of ochratoxin A. Luminescence, 38(9), 1678-1685. https://doi.org/10.1002/bio.4556

Vancouver

Fan YY, Wen J, Li J, Yang XW, Zhang L, Zhang ZQ. Structure‐switching aptasensors for sensitive detection of ochratoxin A. Luminescence. 2023;38(9):1678-1685. doi:10.1002/bio.4556

BibTeX
@article{Fan2023,
  author = {Fan, Yao-Yao and Wen, Jie and Li, Jun and Yang, Xiao-Wen and Zhang, Lu and Zhang, Zhi-Qi},
  title = {Structure‐switching aptasensors for sensitive detection of ochratoxin A},
  journal = {Luminescence},
  year = {2023},
  volume = {38},
  number = {9},
  pages = {1678--1685},
  doi = {10.1002/bio.4556}
}
Kostenlos starten →