EUVIMEDEUVIMED entdecken
Crossref

Flow injection chemiluminescence determination of acetochlor and cartap‐HCl in freshwater samples using an acidic KMnO 4 –rhodamine‐B reaction system

Khair Un Nisa, Attiq Ur Rehman Kakar, Muhammad Asghar, Samiullah, Naqeebullah, Niamatullah, Arif Shah

Luminescence · 2023

DOI: 10.1002/bio.4493 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2023. Verfasst von Khair Un Nisa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan. Hauptthemen laut MEDLINE: Luminescence, Acids. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 69 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A flow injection (FI) methodology using the acidic potassium permanganate (KMnO 4 )–rhodamine‐B (Rh‐B) reaction with chemiluminescence (CL) detection was established to determine acetochlor and cartap‐HCl pesticides in freshwater samples. Experimental parameters were optimized, and Chelex‐100 cationic exchanger mini column and solid‐phase extraction (SPE) were used as phase separation techniques. Linear calibration curves were observed for the standard solutions of acetochlor and cartap‐HCl over the ranges 0.005–2.0 mg L −1 [ y = 1155.8 x + 57.551, R 2 = 0.9999 ( n = 8)] and 0.005–1.0 mg L −1 [ y = 979.76 x + 14.491, R 2 = 0.9998 ( n = 8)] with LODs and LOQs of 7.5 × 10 −4 and 8.0 × 10 −4 mg L −1 (3 σ blank) and 2.5 × 10 −3 and 2.7 × 10 −3 mg L −1 (10 σ blank), respectively, with an injection throughput of 140 h −1 . These methods were used to estimate acetochlor and cartap‐HCl with or without the SPE procedure, respectively, in spiked freshwater samples. Results obtained were not significantly different at a 95% confidence level to those of other reported methods. Recoveries for acetochlor and cartap‐HCl were obtained over the ranges 93–112% (RSD = 1.9–3.6%) and 98–109% (RSD = 1.7–3.8%), respectively. The most probable CL reaction mechanism was explored.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LuminescenceAcidsRhodaminesPotassium PermanganateFresh WaterFlow Injection AnalysisLuminescent MeasurementsToluidinesThiocarbamates

Stichwörter der Autor:innen

acetochlorcartap-HClchemiluminescenceflow injection analysisnatural waterspotassium permanganaterhodamine-B

Substanzen

AcidsRhodaminesPotassium PermanganateacetochlorToluidinescarbamothioic acid, S,S'-(2-(dimethylamino)-1,3-propanediyl) esterThiocarbamates

Autor:innen und Institutionen

  • Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Marti i Franques 1-11, Barcelona, Spain.
  • Directorate, Agriculture Extension and Plant Protection, Quetta, Balochistan, Pakistan.

Zitieren

APA

Nisa, K. U., Kakar, A. U. R., Asghar, M., Samiullah, Naqeebullah, Niamatullah, & Shah, A. (2023). Flow injection chemiluminescence determination of acetochlor and cartap‐HCl in freshwater samples using an acidic KMnO 4 –rhodamine‐B reaction system. Luminescence. https://doi.org/10.1002/bio.4493

Vancouver

Nisa KU, Kakar AUR, Asghar M, Samiullah, Naqeebullah, Niamatullah, et al. Flow injection chemiluminescence determination of acetochlor and cartap‐HCl in freshwater samples using an acidic KMnO 4 –rhodamine‐B reaction system. Luminescence. 2023. doi:10.1002/bio.4493

BibTeX
@article{Nisa2023,
  author = {Nisa, Khair Un and Kakar, Attiq Ur Rehman and Asghar, Muhammad and Samiullah and Naqeebullah and Niamatullah and Shah, Arif},
  title = {Flow injection chemiluminescence determination of acetochlor and cartap‐HCl in freshwater samples using an acidic KMnO 4 –rhodamine‐B reaction system},
  journal = {Luminescence},
  year = {2023},
  doi = {10.1002/bio.4493}
}
Kostenlos starten →