EUVIMEDEUVIMED entdecken
Crossref

Selected ssDNA aptamers–graphene oxide‐based fluorescent biosensor to detect sulfameter in milk

Yanping He iD, Jingrui Zhang, Ruifen Tian, Yuying Lu, Ling Pan, Yuzhong Zhang

Luminescence · 2023

DOI: 10.1002/bio.4473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2023. Verfasst von Yanping He und 5 weiteren Autor:innen. Beteiligte Einrichtung: Anhui Key Laboratory of Chemo/Biosensing, Laboratory of Biosensing and Bioimaging (LOBAB), College of Chemistry and Materials Science, Anhui Normal U…. Hauptthemen laut MEDLINE: Sulfameter, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Anhui University Natural Science Fund project, Postdoctoral Start-up Fund of Anhui Normal University, University Synergy Innovation Program of Anhui Provincial.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The abuse of sulfameter (SME) in animal husbandry can cause drug resistance and toxic or allergic reactions in humans. Therefore, it is very important to establish a simple, inexpensive, and efficient method for detecting SME in food. In this work, we propose a single fluorescent aptamer/graphene oxide (GO)‐based biosensor to detect SME residues in milk. Aptamers that specifically bind to SME were screened using capture‐SELEX and a ssDNA library immobilized on magnetic beads. The 68 active candidate aptamers were chemically synthesized for specificity and affinity characterization. Among the aptamers, the aptamer sulf‐1 revealed the highest affinity (K d = 77 ± 15 nM) to SME and was selected to construct a GO‐based fluorescent biosensor for real milk sample detection. Under optimal conditions, the single fluorescent aptasensor had a wide linear range (R 2 was 0.997) from 7 to 336 ng/ml and a low detection limit of 3.35 ng/ml that was calculated with a 3SD/slope. The single fluorescent method was also validated using SME‐fortified milk samples, showing average recoveries ranging from 99.01% to 104.60% with a relative standard deviation of less than 3.88%. These results demonstrate that this novel aptamer sensor provides an opportunity for sensitive, convenient, and accurate detection of SME residues in milk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SulfameterAptamers, NucleotideBiosensing TechniquesHumansAnimalsMilkAllergensColoring AgentsDNA, Single-StrandedLimit of DetectionGraphite

Stichwörter der Autor:innen

AuNPs colorimetricaptamercapture-SELEXgraphene oxidesulfameter

Substanzen

SulfameterAptamers, NucleotideAllergensColoring AgentsDNA, Single-Strandedgraphene oxideGraphite

Autor:innen und Institutionen

  • Anhui Key Laboratory of Chemo/Biosensing, Laboratory of Biosensing and Bioimaging (LOBAB), College of Chemistry and Materials Science, Anhui Normal University, Wuhu, China.
  • Precision Optical Manufacturing and Testing Centre, Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, Shanghai, China.
  • Collaborative Innovation Center of Recovery and Reconstruction of Degraded Ecosystem in Wanjiang Basin Co-founded by Anhui Province and Ministry of Education, Anhui Normal University, Wuhu, China.

ORCID-Profile: Yanping He

Förderung

  • Anhui University Natural Science Fund project
  • Postdoctoral Start-up Fund of Anhui Normal University
  • University Synergy Innovation Program of Anhui Provincial

Zitieren

APA

He, Y., Zhang, J., Tian, R., Lu, Y., Pan, L., & Zhang, Y. (2023). Selected ssDNA aptamers–graphene oxide‐based fluorescent biosensor to detect sulfameter in milk. Luminescence. https://doi.org/10.1002/bio.4473

Vancouver

He Y, Zhang J, Tian R, Lu Y, Pan L, Zhang Y. Selected ssDNA aptamers–graphene oxide‐based fluorescent biosensor to detect sulfameter in milk. Luminescence. 2023. doi:10.1002/bio.4473

BibTeX
@article{He2023,
  author = {He, Yanping and Zhang, Jingrui and Tian, Ruifen and Lu, Yuying and Pan, Ling and Zhang, Yuzhong},
  title = {Selected ssDNA aptamers–graphene oxide‐based fluorescent biosensor to detect sulfameter in milk},
  journal = {Luminescence},
  year = {2023},
  doi = {10.1002/bio.4473}
}
Kostenlos starten →