EUVIMEDEUVIMED entdecken
Crossref

A ratiometric fluorescent sensor for the detection of phosphate

Jiayi Liu, Yibing Liu, Wei Wang iD, Siqi Zhang, Li Tang, Pinyi Ma iD, Daqian Song, Qiang Fei iD

Luminescence · 2023

DOI: 10.1002/bio.4434 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2023. Verfasst von Jiayi Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Str…. Hauptthemen laut MEDLINE: Metal Nanoparticles, Quantum Dots, Zeolites. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: The Natural Science Foundation of Jilin Province, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past few years, ratiometric fluorescent nanoprobes have garnered substantial interest because of their self‐calibration characteristics. This research developed a ratiometric fluorescent sensor to detect phosphate. Through encapsulating luminescent materials, gold nanoclusters (AuNCs) and carbon dots (CDs) into a zeolitic imidazolate framework‐8 (ZIF‐8), the fluorescence signal of AuNCs was enhanced, while that of CDs was suppressed. After phosphate was added, it could decompose ZIF‐8, and AuNCs and CDs were released, which weakened the fluorescence signal of the AuNCs while restoring that of the CDs. Thereby, this makes CDs/AuNCs@ZIF‐8 a potential fluorescent sensor for phosphate determination. The ratiometric sensor had facile synthesis, good selectivity, and a low detection limit. Therefore, this sensor was an effective tool for the detection of phosphate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metal NanoparticlesQuantum DotsZeolitesFluorescent DyesPhosphatesCopperSpectrometry, FluorescenceCarbonGoldLimit of DetectionCarbon Radioisotopes

Stichwörter der Autor:innen

CDs/AuNCs@ZIF-8carbon dotsgold nanoclustersratiometriczeolitic imidazole frameworks

Substanzen

Fluorescent DyesPhosphatesCopperCarbonGoldZeolitesCarbon-8Carbon Radioisotopes

Autor:innen und Institutionen

  • College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Street 2699, Changchun, China.

ORCID-Profile: Wei Wang, Pinyi Ma, Qiang Fei

Förderung

  • The Natural Science Foundation of Jilin Province, China

Zitieren

APA

Liu, J., Liu, Y., Wang, W., Zhang, S., Tang, L., Ma, P., Song, D., & Fei, Q. (2023). A ratiometric fluorescent sensor for the detection of phosphate. Luminescence. https://doi.org/10.1002/bio.4434

Vancouver

Liu J, Liu Y, Wang W, Zhang S, Tang L, Ma P, et al. A ratiometric fluorescent sensor for the detection of phosphate. Luminescence. 2023. doi:10.1002/bio.4434

BibTeX
@article{Liu2023,
  author = {Liu, Jiayi and Liu, Yibing and Wang, Wei and Zhang, Siqi and Tang, Li and Ma, Pinyi and Song, Daqian and Fei, Qiang},
  title = {A ratiometric fluorescent sensor for the detection of phosphate},
  journal = {Luminescence},
  year = {2023},
  doi = {10.1002/bio.4434}
}
Kostenlos starten →