EUVIMEDEUVIMED entdecken
Crossref

Differences in the Optical Response of MSU and CPP Crystals During Magnetic Orientation: Possibility of Diagnosing Gout and Pseudogout

Yuka Takeuchi, Ryotaro Yoshikawa, Yoshifuru Mitsui, Masakazu Iwasaka, Mizushi Matsuda, Atom Hamasaki

Bioelectromagnetics · 2023

DOI: 10.1002/bem.22444 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioelectromagnetics, 2023. Verfasst von Yuka Takeuchi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Muroran Institute of Technology, Muroran, Japan. Hauptthemen laut MEDLINE: Chondrocalcinosis, Gout. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pseudogout is crystalline arthritis. It has a similar clinical picture to that of gout, and it is difficult to distinguish the two diseases using conventional analysis methods. However, it is important to identify the different crystals responsible for these two cases because the treatment strategies are different. In a previous study, we reported magnetic orientation of monosodium urate (MSU) crystals, which are the causative agent of gout, at the permanent magnet level. In this study, we investigated the effect of an applied magnetic field on calcium pyrophosphate (CPP) crystals, which are the causative agent of pseudogout, and the difference in the magnetic responses of CPP and MSU crystals. We found that the CPP crystals were oriented in a magnetic field on milli‐Tesla order because of the anisotropy of the diamagnetic susceptibility. In addition, the CPP crystals exhibited different anisotropic magnetic properties from those of MSU crystals, which led to a characteristic difference between the orientations of the two crystals. That is, we found that the causative agents of gout and pseudogout responded differently to a magnetic field. This report suggests that the discrimination between CPP and MSU by optical measurements is possible by application of magnetic fields appropriately. © 2023 Bioelectromagnetics Society.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChondrocalcinosisGoutHumansUric AcidCalcium PyrophosphateMagnetic Phenomena

Stichwörter der Autor:innen

diamagnetic materialgout and pseudogoutmagnetic orientation

Substanzen

Uric AcidCalcium Pyrophosphate

Autor:innen und Institutionen

  • Muroran Institute of Technology, Muroran, Japan.
  • Graduate School of Science and Engineering, Kagoshima University, Kagoshima, Japan.
  • RIND, Hiroshima University, Higashi-Hiroshima, Japan.
  • Faculty of Science, Shinshu University, Matsumoto, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Takeuchi, Y., Yoshikawa, R., Mitsui, Y., Iwasaka, M., Matsuda, M., & Hamasaki, A. (2023). Differences in the Optical Response of MSU and CPP Crystals During Magnetic Orientation: Possibility of Diagnosing Gout and Pseudogout. Bioelectromagnetics. https://doi.org/10.1002/bem.22444

Vancouver

Takeuchi Y, Yoshikawa R, Mitsui Y, Iwasaka M, Matsuda M, Hamasaki A. Differences in the Optical Response of MSU and CPP Crystals During Magnetic Orientation: Possibility of Diagnosing Gout and Pseudogout. Bioelectromagnetics. 2023. doi:10.1002/bem.22444

BibTeX
@article{Takeuchi2023,
  author = {Takeuchi, Yuka and Yoshikawa, Ryotaro and Mitsui, Yoshifuru and Iwasaka, Masakazu and Matsuda, Mizushi and Hamasaki, Atom},
  title = {Differences in the Optical Response of MSU and CPP Crystals During Magnetic Orientation: Possibility of Diagnosing Gout and Pseudogout},
  journal = {Bioelectromagnetics},
  year = {2023},
  doi = {10.1002/bem.22444}
}
Kostenlos starten →