EUVIMEDEUVIMED entdecken
Validierungsstudie

Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals

Aubree Boyce, Stephanie Pocius iD

Birth Defects Research · 2026

DOI: 10.1002/bdr2.70119 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Birth Defects Research, 2026. Verfasst von Aubree Boyce und 1 weiteren Autor:innen. Beteiligte Einrichtung: Utah Birth Defect Network, Utah Department of Health and Human Services, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Congenital Abnormalities. Die Arbeit nennt 4 Literaturangaben. Gefördert von: JG CDC HHS, Centers for Disease Control and Prevention.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Public health surveillance is critical for understanding disease burden, yet rigorous case confirmation often introduces significant latency. The Utah Birth Defect Network ( UBDN ) utilizes a multistage active surveillance process that, while highly accurate, is a long and labor‐intensive process. This delay creates a barrier to timely family referrals for early intervention services. This study evaluates whether preliminary surveillance data is sufficiently accurate to initiate public health actions before final clinician confirmation.

Methods

We conducted a retrospective analysis of 27 monitored birth defects for delivery years 2018–2025. Positive predictive values ( PPVs ) were calculated for cases identified during initial medical record review by nonclinical staff compared with the “gold standard” of final clinician‐led confirmation. Analysis was performed using SAS version 9.4, with 95% confidence intervals calculated via the Wilson score method.

Results

Among 1245 unique potential cases, the overall mean PPV was 68% (range: 8%–95%). Accuracy was highest for musculoskeletal defects (95%) and chromosomal anomalies (92%), with gastroschisis (95%), limb deficiencies (93%), and Trisomy 21 (92%) showing high stability. Cardiovascular defects demonstrated lower categorical accuracy (78%), with complex conditions like single ventricle (8%) showing the greatest diagnostic discordance. However, we observed categorical stability, as 77% of reclassified cardiovascular cases remained within the same body system.

Conclusion

Preliminary surveillance reviews demonstrate high diagnostic stability for the majority of monitored conditions. These findings validate the use of preliminary data to trigger early family‐centered referrals, significantly reducing the latency between case confirmation and intervention without compromising the integrity of formal reporting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Congenital AbnormalitiesHumansUtahReferral and ConsultationRetrospective StudiesFemalePopulation SurveillanceMaleInfant, Newborn

Stichwörter der Autor:innen

birth defectspositive predictive valuesurveillance

Autor:innen und Institutionen

  • Utah Birth Defect Network, Utah Department of Health and Human Services, Salt Lake City, Utah, USA.

ORCID-Profile: Stephanie Pocius

Förderung

  • JG CDC HHS
  • Centers for Disease Control and Prevention

Zitieren

APA

Boyce, A., & Pocius, S. (2026). Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals. Birth Defects Research. https://doi.org/10.1002/bdr2.70119

Vancouver

Boyce A, Pocius S. Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals. Birth Defects Research. 2026. doi:10.1002/bdr2.70119

BibTeX
@article{Boyce2026,
  author = {Boyce, Aubree and Pocius, Stephanie},
  title = {Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals},
  journal = {Birth Defects Research},
  year = {2026},
  doi = {10.1002/bdr2.70119}
}
Kostenlos starten →