Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals
Birth Defects Research · 2026
DOI: 10.1002/bdr2.70119 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Birth Defects Research, 2026. Verfasst von Aubree Boyce und 1 weiteren Autor:innen. Beteiligte Einrichtung: Utah Birth Defect Network, Utah Department of Health and Human Services, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Congenital Abnormalities. Die Arbeit nennt 4 Literaturangaben. Gefördert von: JG CDC HHS, Centers for Disease Control and Prevention.
Abstract (Originalsprache)
Background
Public health surveillance is critical for understanding disease burden, yet rigorous case confirmation often introduces significant latency. The Utah Birth Defect Network ( UBDN ) utilizes a multistage active surveillance process that, while highly accurate, is a long and labor‐intensive process. This delay creates a barrier to timely family referrals for early intervention services. This study evaluates whether preliminary surveillance data is sufficiently accurate to initiate public health actions before final clinician confirmation.
Methods
We conducted a retrospective analysis of 27 monitored birth defects for delivery years 2018–2025. Positive predictive values ( PPVs ) were calculated for cases identified during initial medical record review by nonclinical staff compared with the “gold standard” of final clinician‐led confirmation. Analysis was performed using SAS version 9.4, with 95% confidence intervals calculated via the Wilson score method.
Results
Among 1245 unique potential cases, the overall mean PPV was 68% (range: 8%–95%). Accuracy was highest for musculoskeletal defects (95%) and chromosomal anomalies (92%), with gastroschisis (95%), limb deficiencies (93%), and Trisomy 21 (92%) showing high stability. Cardiovascular defects demonstrated lower categorical accuracy (78%), with complex conditions like single ventricle (8%) showing the greatest diagnostic discordance. However, we observed categorical stability, as 77% of reclassified cardiovascular cases remained within the same body system.
Conclusion
Preliminary surveillance reviews demonstrate high diagnostic stability for the majority of monitored conditions. These findings validate the use of preliminary data to trigger early family‐centered referrals, significantly reducing the latency between case confirmation and intervention without compromising the integrity of formal reporting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Utah Birth Defect Network, Utah Department of Health and Human Services, Salt Lake City, Utah, USA.
ORCID-Profile: Stephanie Pocius
Förderung
- JG CDC HHS
- Centers for Disease Control and Prevention
Zitieren
APA
Boyce, A., & Pocius, S. (2026). Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals. Birth Defects Research. https://doi.org/10.1002/bdr2.70119
Vancouver
Boyce A, Pocius S. Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals. Birth Defects Research. 2026. doi:10.1002/bdr2.70119
BibTeX
@article{Boyce2026,
author = {Boyce, Aubree and Pocius, Stephanie},
title = {Accuracy of Preliminary Birth Defect Surveillance in Utah: A Validation Study Supporting Timely Family Referrals},
journal = {Birth Defects Research},
year = {2026},
doi = {10.1002/bdr2.70119}
}
EUVIMED