EUVIMEDEUVIMED entdecken
Crossref

Utility of Electronic Case Reporting for Case Identification in Texas Birth Defects Surveillance

R P Allred iD, C Yantz, H Jeon, R Howell iD, M Kilburn, C Shumate iD

Birth Defects Research · 2025

DOI: 10.1002/bdr2.70004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Birth Defects Research, 2025. Verfasst von R P Allred und 5 weiteren Autor:innen. Beteiligte Einrichtung: Birth Defects Epidemiology and Surveillance Branch, Texas Department of State Health Services, Austin, Texas, USA. Hauptthemen laut MEDLINE: Congenital Abnormalities, Electronic Health Records, Population Surveillance. Die Arbeit nennt 19 Literaturangaben. Gefördert von: CDC HHS, Texas Department of State Health Services, Centers for Disease Control and Prevention.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The utility of electronic case reporting (eCR) in birth defects surveillance is unknown. This evaluation assessed whether electronic initial case reports (eICRs) can serve as a potential case identification source and how eICRs compare to electronic health records (EHRs) in capturing demographic and diagnostic information.

Methods

Cases were identified from the Texas Birth Defects Registry's eCR data stream. Upon case confirmation, the EHR was requested and abstracted following routine abstraction processes. Next, the eICR html file was abstracted. The number, range, and mean of coded birth defects, as well as pre‐ and postnatal procedures were calculated for both data sources. Concordance between abstracted variables from the EHR and the eICR was evaluated for non‐missing data using weighted kappa agreement statistics in SAS.

Results

There were many missing data from the eICR. Fewer birth defects and pre‐ and postnatal procedures were reported in the eICR compared to the EHR. Most variables had low concordance, while a few variables had high concordance (e.g., infant sex [kappa = 0.95], infant birthdate [kappa = 0.99], primary defect code/diagnosis [kappa = 0.83 using 6‐digit British Pediatric Association [BPA] codes; kappa = 0.92, 4‐digit BPA codes]). Conclusions eCR may be a viable source for timely potential case identification and may also facilitate timelier referral to social services among eligible cases. eCR data files are not standardized across facilities, lack critical variables permitting examination of birth defect risk factors, and are generally not a comprehensive resource for all pertinent data related to a birth defect case.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Congenital AbnormalitiesElectronic Health RecordsPopulation SurveillanceHumansTexasRegistriesFemaleMaleInfant, Newborn

Stichwörter der Autor:innen

birth defects surveillancecase identificationelectronic case reportelectronic health recordelectronic initial case report

Autor:innen und Institutionen

  • Birth Defects Epidemiology and Surveillance Branch, Texas Department of State Health Services, Austin, Texas, USA.

ORCID-Profile: R P Allred, R Howell, C Shumate

Förderung

  • CDC HHS
  • Texas Department of State Health Services
  • Centers for Disease Control and Prevention

Zitieren

APA

Allred, R. P., Yantz, C., Jeon, H., Howell, R., Kilburn, M., & Shumate, C. (2025). Utility of Electronic Case Reporting for Case Identification in Texas Birth Defects Surveillance. Birth Defects Research. https://doi.org/10.1002/bdr2.70004

Vancouver

Allred RP, Yantz C, Jeon H, Howell R, Kilburn M, Shumate C. Utility of Electronic Case Reporting for Case Identification in Texas Birth Defects Surveillance. Birth Defects Research. 2025. doi:10.1002/bdr2.70004

BibTeX
@article{Allred2025,
  author = {Allred, R P and Yantz, C and Jeon, H and Howell, R and Kilburn, M and Shumate, C},
  title = {Utility of Electronic Case Reporting for Case Identification in Texas Birth Defects Surveillance},
  journal = {Birth Defects Research},
  year = {2025},
  doi = {10.1002/bdr2.70004}
}
Kostenlos starten →