EUVIMEDEUVIMED entdecken
Open Access

A Quartz Tuning Fork‐Based Immunosensor for Detection of Kidney Injury Molecule‐1: A New Working Electrode for Electrochemical Applications

Şeyma Şentürk Özkan, Mustafa Kemal Sezgintürk

Biotechnology and Applied Biochemistry · 2026

DOI: 10.1002/bab.70128 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology and Applied Biochemistry, 2026. Verfasst von Şeyma Şentürk Özkan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye. Hauptthemen laut MEDLINE: Hepatitis A Virus Cellular Receptor 1, Biosensing Techniques, Electrochemical Techniques, Quartz. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Çanakkale Onsekiz Mart Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kidney injury molecule‐1 (KIM‐1) is a Type I transmembrane glycoprotein and is a potential biomarker for detecting kidney damage, as its urinary levels fluctuate in cases of acute kidney injury. In this study, an electrochemical immunosensor was developed for the first time using a quartz tuning fork (QTF) working electrode to detect the KIM‐1 biomarker. The gold‐tipped QTF electrode surface was modified with 11‐mercaptoundecanoic acid (11‐MUA) to form a self‐assembled monolayer (SAM). To construct the biosensor, extensive optimization studies were conducted on the fabrication parameters, followed by characterization and real urine sample testing to evaluate its applicability. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods were utilized in all electrochemical experiments. Morphological changes on the QTF electrode surface were examined using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The developed electrochemical KIM‐1 immunosensor demonstrated highly promising performance, exhibiting an exceptionally wide detection range (0.05–250 fg/mL). Furthermore, the dissociation constant (Kd) of the interaction between KIM‐1 and its antibody was successfully calculated using the Hill equation, on the basis of the QTF‐based system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hepatitis A Virus Cellular Receptor 1Biosensing TechniquesElectrochemical TechniquesQuartzElectrodesHumansImmunoassayDielectric SpectroscopySulfhydryl Compounds

Stichwörter der Autor:innen

11‐mercaptoundecanoic acid (11‐MUA)immunosensorkidney injurykidney injury molecule‐1 (KIM‐1)quartz tuning fork (QTF) electrode

Substanzen

Hepatitis A Virus Cellular Receptor 1HAVCR1 protein, humanQuartzSulfhydryl Compounds

Autor:innen und Institutionen

  • Bioengineering Department, Engineering Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye.

Förderung

  • Çanakkale Onsekiz Mart Üniversitesi

Zitieren

APA

Özkan, Ş. Ş., & Sezgintürk, M. K. (2026). A Quartz Tuning Fork‐Based Immunosensor for Detection of Kidney Injury Molecule‐1: A New Working Electrode for Electrochemical Applications. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.70128

Vancouver

Özkan ŞŞ, Sezgintürk MK. A Quartz Tuning Fork‐Based Immunosensor for Detection of Kidney Injury Molecule‐1: A New Working Electrode for Electrochemical Applications. Biotechnology and Applied Biochemistry. 2026. doi:10.1002/bab.70128

BibTeX
@article{zkan2026,
  author = {Özkan, Şeyma Şentürk and Sezgintürk, Mustafa Kemal},
  title = {A Quartz Tuning Fork‐Based Immunosensor for Detection of Kidney Injury Molecule‐1: A New Working Electrode for Electrochemical Applications},
  journal = {Biotechnology and Applied Biochemistry},
  year = {2026},
  doi = {10.1002/bab.70128}
}
Kostenlos starten →