Considerations for large building water quality after extended stagnation
AWWA Water Science · 2020-07 · 2 (4)
DOI: 10.1002/aws2.1186 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift AWWA Water Science, online erschienen am 06.08.2020. Verfasst von Caitlin R Proctor und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials…. Die Arbeit wurde bisher 114-mal zitiert (Crossref) und nennt 156 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, U.S. Environmental Protection Agency.
Abstract (Originalsprache)
The unprecedented number of building closures related to the coronavirus disease (COVID‐19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer‐reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials Engineering Purdue University West Lafayette Indiana.
- Department of Civil and Environmental Engineering Virginia Tech Blacksburg Virginia.
- Legionella Risk Management, Inc. Chalfont Pennsylvania.
- Department of Civil Engineering University of Memphis Memphis Tennessee.
- School of Sustainable Engineering and the Built Environment Arizona State University Tempe Arizona.
- Department of Civil and Environmental Engineering Northeastern University Boston Massachusetts.
Förderung
- NIEHS NIH HHS
- U.S. Environmental Protection Agency
Zitieren
APA
Proctor, C. R., Rhoads, W. J., Keane, T., Salehi, M., Hamilton, K., Pieper, K. J., Cwiertny, D. M., Prévost, M., & Whelton, A. J. (2020). Considerations for large building water quality after extended stagnation. AWWA Water Science, 2(4). https://doi.org/10.1002/aws2.1186
Vancouver
Proctor CR, Rhoads WJ, Keane T, Salehi M, Hamilton K, Pieper KJ, et al. Considerations for large building water quality after extended stagnation. AWWA Water Science. 2020;2(4). doi:10.1002/aws2.1186
BibTeX
@article{Proctor2020,
author = {Proctor, Caitlin R and Rhoads, William J and Keane, Tim and Salehi, Maryam and Hamilton, Kerry and Pieper, Kelsey J and Cwiertny, David M and Prévost, Michele and Whelton, Andrew J},
title = {Considerations for large building water quality after extended stagnation},
journal = {AWWA Water Science},
year = {2020},
volume = {2},
number = {4},
doi = {10.1002/aws2.1186}
}
EUVIMED