EUVIMEDEUVIMED entdecken
Crossref

Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns

Chao Zeng, Ariel Atkinson, Naushita Sharma, Harsh Ashani, Annika Hjelmstad, Krishishvar Venkatesh, Paul Westerhoff

AWWA Water Science · 2020-01 · 2 (1)

DOI: 10.1002/aws2.1172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AWWA Water Science, online erschienen am 27.02.2020. Verfasst von Chao Zeng und 6 weiteren Autor:innen. Die Arbeit wurde bisher 108-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human exposure to per‐ and polyfluoroalkyl substances (PFAS) in drinking water is of growing concern as a result of increasing reports of occurrence and potential regulation. Adsorption of PFAS by granular activated carbon (GAC) or ion exchange (IX) resin is a suitable treatment technique. However, few studies compare PFAS removal in continuous flow GAC or IX adsorption systems using real drinking water sources. In this study, rapid small‐scale column tests (RSSCTs) were used to investigate the effects of PFAS type and chain length on adsorption by GAC and IX resin for six groundwaters used as drinking water supplies. Seven PFAS substances with chain lengths of C4–C9 were detected in the groundwaters with the sum of their concentrations (ΣPFAS) ranging from 156 to 7,044 ng/L. Adsorption capacities ( q ΣPFAS ) were calculated to compare the removal capacity among different sorbents and q ΣPFAS values ranged from 10.3 to 228 ng PFAS/mg sorbent after about 100,000 bed volumes treated. Coal‐based GACs had higher adsorption capacity compared with coconutshell‐based GAC, which was likely due to higher mesopore and macropore volumes. IX resins performed better than GAC in removing PFAS, but they were not effective in treating short‐chain perfluorocarboxylic acids (PFCAs). Perfluorosulfonic acids (PFSAs) broke through later than PFCAs with the same chain length. Within PFSA or PFCA classes, shorter‐chain PFAS species always broke through before longer‐chain PFAS. Statistical analysis demonstrated that PFAS with higher hydrophobicity and molecular weight are more amenable to GAC adsorption. Empirical models were developed and predicted PFAS breakthrough. By quantifying PFAS selectivity and removal efficiency, this work provides benchmark data for commercially available treatment technologies and guidance toward specific PFAS classes for which new treatment technologies may be most beneficial.

Förderung

  • National Science Foundation

Zitieren

APA

Zeng, C., Atkinson, A., Sharma, N., Ashani, H., Hjelmstad, A., Venkatesh, K., & Westerhoff, P. (2020). Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns. AWWA Water Science, 2(1). https://doi.org/10.1002/aws2.1172

Vancouver

Zeng C, Atkinson A, Sharma N, Ashani H, Hjelmstad A, Venkatesh K, et al. Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns. AWWA Water Science. 2020;2(1). doi:10.1002/aws2.1172

BibTeX
@article{Zeng2020,
  author = {Zeng, Chao and Atkinson, Ariel and Sharma, Naushita and Ashani, Harsh and Hjelmstad, Annika and Venkatesh, Krishishvar and Westerhoff, Paul},
  title = {Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns},
  journal = {AWWA Water Science},
  year = {2020},
  volume = {2},
  number = {1},
  doi = {10.1002/aws2.1172}
}
Kostenlos starten →