Open Extensor Carpi Radialis Brevis Debridement Augmented by Bioinductive Collagen Implant: Indications and Surgical Technique
Arthroscopy Techniques · 22.11.2026
DOI: 10.1002/atn2.70398 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy Techniques, online erschienen am 22.11.2026. Verfasst von Cassandra Keinath und 6 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Lateral epicondylitis is a common cause of elbow pain that typically resolves with conservative management. For patients with persistent symptoms and failed nonoperative treatment, surgical intervention may be considered. We describe a surgical technique for open extensor carpi radialis brevis debridement with augmentation using a bovine‐derived bioinductive collagen implant. The procedure involves direct visualization and excision of degenerative tendon, followed by extensor carpi radialis longus tendon repair using a suture anchor. A bioinductive patch is secured over the repair using absorbable staples and suture. This technique builds on principles established in rotator cuff repair, where bioinductive implants have shown increased tendon thickness, organized tissue regeneration, and reduced retear rates. Although no studies currently assess the efficacy of collagen augmentation in lateral epicondylitis, its hypothesized benefit lies in enhancing tendon healing and promoting growth of new tissue after debridement. Contraindications include active infection and allergy to implant materials. Postoperative rehabilitation includes early range of motion and gradual strengthening. This technique provides a reproducible approach to augment open extensor carpi radialis brevis debridement and warrants further studies to evaluate the effect of bioinductive patch augmentation and outcomes in patients with recalcitrant lateral epicondylitis.
Zitieren
APA
Keinath, C., Kasto, J., Andrews, E., Obinero, C., Dalby, D., Mahylis, J., & Muh, S. (2026). Open Extensor Carpi Radialis Brevis Debridement Augmented by Bioinductive Collagen Implant: Indications and Surgical Technique. Arthroscopy Techniques. https://doi.org/10.1002/atn2.70398
Vancouver
Keinath C, Kasto J, Andrews E, Obinero C, Dalby D, Mahylis J, et al. Open Extensor Carpi Radialis Brevis Debridement Augmented by Bioinductive Collagen Implant: Indications and Surgical Technique. Arthroscopy Techniques. 2026. doi:10.1002/atn2.70398
BibTeX
@article{Keinath2026,
author = {Keinath, Cassandra and Kasto, Johnny and Andrews, Erickson and Obinero, Chimdi and Dalby, Drew and Mahylis, Jared and Muh, Stephanie},
title = {Open Extensor Carpi Radialis Brevis Debridement Augmented by Bioinductive Collagen Implant: Indications and Surgical Technique},
journal = {Arthroscopy Techniques},
year = {2026},
doi = {10.1002/atn2.70398}
}
EUVIMED