EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasensitive miRNA Detection by AuNP‐based 3D DNA Walker and Catalytic Hairpin Assembly (CHA) Cascade Amplification for Early Cancer Diagnosis

Junyou Li, Hung-Wing Li iD

Chemistry – An Asian Journal · 2023

DOI: 10.1002/asia.202300367 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemistry – An Asian Journal, 2023. Verfasst von Junyou Li und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, The Chinese University of Hong Kong Shatin, New Territories, Hong Kong, China. Hauptthemen laut MEDLINE: MicroRNAs, Metal Nanoparticles, Gold, Biosensing Techniques. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hong Kong Research Grant Council, Chinese University of Hong Kong (CUHK).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

By combining exquisitely designed hairpins with the catalytic hairpin assembly (CHA) to form tripedal DNA walkers driven by enzyme, we constructed a 3D DNA walker with accordingly complementary hairpins attached on gold nanoparticles (AuNPs) and sensitive fluorescence sensing system for the sensitive detection of target miRNA‐21 (miR‐21). The presence of miR‐21 triggers the CHA among three hairpins (HP1, HP2, and HP3), which lead to the formation of the tripedal DNA walkers. For the walking trajectories, FAM‐labeled hairpins (HP4) were attached to the surface of AuNPs, the fluorescence of which was initially quenched due to its close proximity to AuNPs. After the binding/cleaving/moving process of tripedal DNA walkers with HP4 driven by Exonuclease III (Exo III), a number of single‐stranded DNAs (ssDNAs) will be released with FAM fluorescence recovered. Benefiting from the DNA walker and CHA cascade amplification, the proposed sensing strategy showed remarkable improvement in sensitivity with the LOD of 42 aM. Owing to the precise design of the system, this method exhibited excellent specificity to distinguish miR‐21 from its single‐, double‐mismatched sequences and non‐complementary sequences, showing great versatility and potential for the biological analysis and early disease diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsMetal NanoparticlesGoldBiosensing TechniquesDNANeoplasmsHumansSpectrometry, FluorescenceNucleic Acid Amplification TechniquesLimit of DetectionCatalysisInverted Repeat SequencesExodeoxyribonucleases

Stichwörter der Autor:innen

CHAcascade amplificationfluorescencemiR-21 detectiontripedal DNA walker

Substanzen

MicroRNAsGoldMIRN21 microRNA, humanDNAexodeoxyribonuclease IIIExodeoxyribonucleases

Autor:innen und Institutionen

  • Department of Chemistry, The Chinese University of Hong Kong Shatin, New Territories, Hong Kong, China.

ORCID-Profile: Hung-Wing Li

Förderung

  • Hong Kong Research Grant Council
  • Chinese University of Hong Kong (CUHK)

Zitieren

APA

Li, J., & Li, H. W. (2023). Ultrasensitive miRNA Detection by AuNP‐based 3D DNA Walker and Catalytic Hairpin Assembly (CHA) Cascade Amplification for Early Cancer Diagnosis. Chemistry – An Asian Journal. https://doi.org/10.1002/asia.202300367

Vancouver

Li J, Li HW. Ultrasensitive miRNA Detection by AuNP‐based 3D DNA Walker and Catalytic Hairpin Assembly (CHA) Cascade Amplification for Early Cancer Diagnosis. Chemistry – An Asian Journal. 2023. doi:10.1002/asia.202300367

BibTeX
@article{Li2023,
  author = {Li, Junyou and Li, Hung-Wing},
  title = {Ultrasensitive miRNA Detection by AuNP‐based 3D DNA Walker and Catalytic Hairpin Assembly (CHA) Cascade Amplification for Early Cancer Diagnosis},
  journal = {Chemistry – An Asian Journal},
  year = {2023},
  doi = {10.1002/asia.202300367}
}
Kostenlos starten →