EUVIMEDEUVIMED entdecken
Vergleichsstudie

Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair

Vasileios Giovanoulis iD, Christos Koutserimpas iD, Fabricio Luciano Vassallo, Nikolaos Lepidas iD, Derrick Guo iD, Mathieu Thaunat iD

Arthroscopy · 2026-11 · 42 (11) · 2520-2527

DOI: 10.1002/arj.70434 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Arthroscopy, online erschienen am 09.07.2026. Verfasst von Vasileios Giovanoulis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ramsay Santé, Hôpital privé Jean Mermoz, Centre Orthopédique Santy, FIFA Medical Center of Excellence, Lyon, France. Hauptthemen laut MEDLINE: Suture Techniques, Patient Reported Outcome Measures, Surgical Stapling, Arthroscopy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare outcomes of endoscopic gluteus medius repair using the suture staple technique versus a control side‐to‐side repair at ≥24‐month follow‐up.

Methods

A retrospective, single‐center study from January 2015 to December 2021 was conducted with data collected during a transitional period where evolving surgical practices led to the adoption of the suture staple technique. Included were all patients with ≥2 years of follow‐up and ≥6 months of well‐structured nonoperative treatment. Outcomes were assessed using the modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, and visual analog scale. Statistical analyses included Student's t‐test and Wilcoxon test for comparing group differences, with significance set at P < .05.

Results

Sixty‐one patients were analyzed (control n = 31; suture staple n = 30). The overall mean age was 65.7 (standard deviation [SD] = 10.4 years); control (65.2 SD = 10.7 years), and suture stable group (66.1, SD 10.3 years). The cohort was predominantly female (78.7%), including 80.6% women in the control group and 76.7% in the suture stable group. Follow‐up averaged 72.7 months (SD 34.4; range 24‐142). Follow‐up was significantly longer in the control side‐to‐side group than in the suture staple group (mean 82.8 SD 31.6 vs 62.3 SD 34.6 months; P = .0180). The modified Harris Hip Score increased from 32.7 (SD 19.1) preoperatively to 71.0 (SD 18.2) postoperatively, with no significant difference between groups ( P = .5322). Victorian Institute of Sport Assessment ‐ Gluteal improved by 40.2 units (SD 22.6), with 85.2% achieving the minimal clinically important difference of 11.3 ( P = .4635). Visual analog scale scores decreased from 7.7 (SD 2.1) to 2.7 (SD 2.0), with 90.2% achieving the minimal clinically important difference of 1.3 with no significant difference ( P = .1058). Sex‐disaggregated analyses revealed no significant between‐technique differences in men or women for modified Harris Hip Score, Victorian Institute of Sport Assessment ‐ Gluteal, or visual analog scale (men: P = .9318, .4400, and .4276; women: P = .4288, .7501, and .2101, respectively). Both techniques provided comparable functional and pain relief outcomes.

Conclusion

The suture staple technique and side‐to‐side technique are effective for endoscopic gluteus medius tendon repair, achieving significant functional and pain score improvements over a mean follow‐up of 6 years. Level of Evidence Level III, retrospective comparative cohort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Suture TechniquesPatient Reported Outcome MeasuresSurgical StaplingArthroscopyMuscle, SkeletalEndoscopyTendon InjuriesHumansFemaleRetrospective StudiesMaleAgedButtocksMiddle AgedTreatment Outcome

Autor:innen und Institutionen

  • Ramsay Santé, Hôpital privé Jean Mermoz, Centre Orthopédique Santy, FIFA Medical Center of Excellence, Lyon, France.
  • Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Hospices Civils de Lyon, Lyon, France.
  • Department of Orthopaedic, Centre Hospitalier de Versailles, Le Chesnay, France.
  • 2nd Department of Orthopaedic Surgery, 'Hygeia' General Hospital of Athens, Athens, Greece.
  • School of Rehabilitation Health Sciences, University of Patras, Patras, Greece.
  • Department of Orthopaedic & Trauma Surgery, HUCE -Hospital Universitario de Ceuta S/n Colmenar, Ceuta, Spain.

ORCID-Profile: Vasileios Giovanoulis, Christos Koutserimpas, Nikolaos Lepidas, Derrick Guo, Mathieu Thaunat

Zitieren

APA

Giovanoulis, V., Koutserimpas, C., Vassallo, F. L., Lepidas, N., Guo, D., & Thaunat, M. (2026). Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair. Arthroscopy, 42(11), 2520-2527. https://doi.org/10.1002/arj.70434

Vancouver

Giovanoulis V, Koutserimpas C, Vassallo FL, Lepidas N, Guo D, Thaunat M. Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair. Arthroscopy. 2026;42(11):2520-2527. doi:10.1002/arj.70434

BibTeX
@article{Giovanoulis2026,
  author = {Giovanoulis, Vasileios and Koutserimpas, Christos and Vassallo, Fabricio Luciano and Lepidas, Nikolaos and Guo, Derrick and Thaunat, Mathieu},
  title = {Equivalent Patient‐Reported Outcomes for Suture Staple Technique Versus Control Side‐To‐Side Endoscopic Gluteus Medius Repair},
  journal = {Arthroscopy},
  year = {2026},
  volume = {42},
  number = {11},
  pages = {2520--2527},
  doi = {10.1002/arj.70434}
}
Kostenlos starten →