Damaging Noise Levels Are Seen in Arthroscopic Surgery
Arthroscopy · 2026-06 · 42 (6) · 1052-1058
DOI: 10.1002/arj.70226 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy, online erschienen am 15.05.2026. Verfasst von Hannah R Popper und 6 weiteren Autor:innen. Beteiligte Einrichtung: Jefferson Health New Jersey, Stratford, New Jersey, U.S.A. Hauptthemen laut MEDLINE: Arthroscopy, Noise, Occupational, Orthopedic Surgeons, Hearing Loss, Noise-Induced. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
Purpose
To determine whether orthopaedic surgeons performing arthroscopic shoulder, hip, and knee surgeries are exposed to damaging noise levels, while also comparing noise levels between these different arthroscopic procedures and further analyzing common arthroscopic knee procedures such as meniscectomy and anterior cruciate ligament reconstruction.
Methods
A retrospective review was conducted using prospectively collected intraoperative audio measurements during arthroscopic procedures from March 2021 to February 2023. Metrics included the maximum decibel (dB) level (MDL), time‐weighted average (TWA), dose, and projected dose. The MDL is the greatest level of noise during each case, TWA is the average dB level over an 8‐hour period, dose is the percentage of allowable daily noise, and projected dose extrapolates exposure over 8 hours.
Results
Out of 124 recordings (13 baseline, 111 procedural—10 hip, 40 shoulder, and 61 knee), MDL exceeded >85 dB for all procedures, highest for shoulder procedures (117.5 dB, P < .001). The TWA remained
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Jefferson Health New Jersey, Stratford, New Jersey, U.S.A.
- University of Maryland School of Medicine, Baltimore, Maryland, U.S.A.
- Rothman Orthopaedic Institute, Philadelphia, Pennsylvania, U.S.A.
ORCID-Profile: Hannah R Popper, William Baker, Stephanie Kwan
Zitieren
APA
Popper, H. R., Baker, W., Fliegel, B., Kwan, S., Sherman, M., Austin, L., & Salvo, J. (2026). Damaging Noise Levels Are Seen in Arthroscopic Surgery. Arthroscopy, 42(6), 1052-1058. https://doi.org/10.1002/arj.70226
Vancouver
Popper HR, Baker W, Fliegel B, Kwan S, Sherman M, Austin L, et al. Damaging Noise Levels Are Seen in Arthroscopic Surgery. Arthroscopy. 2026;42(6):1052-1058. doi:10.1002/arj.70226
BibTeX
@article{Popper2026,
author = {Popper, Hannah R and Baker, William and Fliegel, Brian and Kwan, Stephanie and Sherman, Matthew and Austin, Luke and Salvo, John},
title = {Damaging Noise Levels Are Seen in Arthroscopic Surgery},
journal = {Arthroscopy},
year = {2026},
volume = {42},
number = {6},
pages = {1052--1058},
doi = {10.1002/arj.70226}
}