Improved Patient‐Reported Outcomes Following Human Dermal Allograft Patch Augmentation With Footprint Medialization in Arthroscopic Partial Repair of Retracted Rotator Cuff Tears
Arthroscopy · 2026
DOI: 10.1002/arj.70064 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy, 2026. Verfasst von Seong Hun Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, National Health Insurance Service Ilsan Hospital, Gyeonggi, Republic of Korea. Hauptthemen laut MEDLINE: Arthroscopy, Rotator Cuff Injuries, Patient Reported Outcome Measures, Skin Transplantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the clinical and radiologic outcomes of arthroscopic partial repair combined with human dermal allograft (HDA) patch augmentation in patients with retracted rotator cuff tears larger than 2.5 cm, where complete footprint coverage was not feasible.
Methods
We prospectively enrolled patients with retracted full‐thickness rotator cuff tears measuring larger than 2.5 cm. Indication for human dermal allograft patch augmentation was residual footprint exposure exceeding 1.5 × 1.5 cm after arthroscopic rotator cuff repair with footprint medialization less than 1 cm. Clinical outcomes were assessed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, Single Assessment Numeric Evaluation, Visual Analog Scale for pain, and active range of motion. The minimal clinically important difference was calculated using the American Shoulder and Elbow Surgeons score. Retear was evaluated via magnetic resonance imaging at 6 months and annual ultrasound examination.
Results
Forty patients (mean age 64.5 ± 8.8 years) were included. The minimum follow‐up was 17 months, with a mean of 19.7 ± 2.5 months (range, 17‐28 months). At final follow‐up, clinical outcomes improved significantly: Visual Analog Scale from 4.9 ± 1.8 to 0.4 ± 0.5, Single Assessment Numeric Evaluation from 31.7 ± 18.2 to 94.1 ± 8.3, American Shoulder and Elbow Surgeons from 68.4 ± 16.8 to 93.7 ± 5.3, and Constant from 61.1 ± 15.1 to 89.2 ± 5.7 ( P < .001). Active range of motion also increased significantly ( P < .001). All patients exceeded the minimal clinically important difference. Retear occurred in 3 patients (7.5%) on 6‐month magnetic resonance imaging. No additional retears were found on annual ultrasound examination.
Conclusions
Arthroscopic partial repair with footprint medialization and human dermal allograft patch augmentation yielded significant improvements in patient‐reported outcomes and a low retear rate for retracted rotator cuff tears, especially when the tear size more than 2.5 cm and residual footprint exposed area is exceeding 1.5 × 1.5 cm after medialization to less than 1 cm. Level of Evidence Level IV, retrospective case series.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopedic Surgery, National Health Insurance Service Ilsan Hospital, Gyeonggi, Republic of Korea.
- Department of Orthopedic Surgery, College of Medicine, Ewha Womans University Seoul Hospital, Seoul, Republic of Korea.
ORCID-Profile: Seong Hun Kim, Sang-Jin Shin
Zitieren
APA
Kim, S. H., & Shin, S. J. (2026). Improved Patient‐Reported Outcomes Following Human Dermal Allograft Patch Augmentation With Footprint Medialization in Arthroscopic Partial Repair of Retracted Rotator Cuff Tears. Arthroscopy. https://doi.org/10.1002/arj.70064
Vancouver
Kim SH, Shin SJ. Improved Patient‐Reported Outcomes Following Human Dermal Allograft Patch Augmentation With Footprint Medialization in Arthroscopic Partial Repair of Retracted Rotator Cuff Tears. Arthroscopy. 2026. doi:10.1002/arj.70064
BibTeX
@article{Kim2026,
author = {Kim, Seong Hun and Shin, Sang-Jin},
title = {Improved Patient‐Reported Outcomes Following Human Dermal Allograft Patch Augmentation With Footprint Medialization in Arthroscopic Partial Repair of Retracted Rotator Cuff Tears},
journal = {Arthroscopy},
year = {2026},
doi = {10.1002/arj.70064}
}
EUVIMED