Posterior Approach Ramp Lesion Repair Using an All‐Inside Meniscal Repair Device in Hamstring Anterior Cruciate Ligament Reconstruction and Lateral Extra‐articular Tenodesis Shows Superior Healing Over Anterior Approach
Arthroscopy · 2026
DOI: 10.1002/arj.70059 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Arthroscopy, 2026. Verfasst von Ji Hyun Ahn und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroscopy, Anterior Cruciate Ligament Reconstruction, Tibial Meniscus Injuries, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Purpose
To compare the second‐look arthroscopic healing status, functional outcomes, and complications between anterior‐ and posterior‐approach repairs for medial meniscal ramp lesions using all‐inside meniscal repair devices in patients undergoing anterior cruciate ligament reconstruction.
Methods
This retrospective study included patients with anterior cruciate ligament injuries who underwent medial meniscal posterior horn ramp lesion repair between January 2015 and January 2019. Inclusion criteria were a minimum follow‐up of 2 years and second‐look arthroscopy performed approximately 1 year postoperatively. Patients were divided into an anterior‐approach repair group and a posterior‐approach repair group. Postoperative healing status was classifiedas follows: (1) healed, (2) partially healed, and (3) failed. Clinical outcomes (anterior laxity, pivot shift, Lysholm score, subjective International Knee Documentation Committee score, Knee injury and Osteoarthritis Outcome Score, Tegner score, and meniscal retear rate) according to the repair technique were compared between the two groups.
Results
Eighty‐one patients with anterior cruciate ligament injuries underwent medial meniscal posterior horn ramp lesion repair and were divided into an anterior‐approach repair group (n = 40) and a posterior‐approach repair group (n = 41). In the posterior‐approach repair group, 40 patients (97.6%) showed complete healing compared with 21 patients (52.5%) in the anterior‐approach repair group. Partial healing was observed in 12 patients (14.8%), with 1 patient (2.4%) in the posterior‐approach repair group and 11 patients (27.5%) in the anterior‐approach repair group. Failure of healing occurred in 8 patients (9.9%), all of whom were in the anterior approach group (20%). There were no significant differences in postoperative Tegner, Lysholm, International Knee Documentation Committee score, and Knee injury and Osteoarthritis Outcome Score scores between the 2 groups. The minimum clinically important difference was fixed at IKDC = 18.9, Lysholm = 10.1, and Tegner score = 1.0.
Conclusions
Posterior‐approach repair of medial meniscal posterior horn ramp lesions using the all‐inside meniscal repair devices resulted in superior healing compared with the anterior‐approach. Level of Evidence Level III, retrospective comparative study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Ji Hyun Ahn, Dong-Wook Son
Zitieren
APA
Ahn, J. H., & Son, D. W. (2026). Posterior Approach Ramp Lesion Repair Using an All‐Inside Meniscal Repair Device in Hamstring Anterior Cruciate Ligament Reconstruction and Lateral Extra‐articular Tenodesis Shows Superior Healing Over Anterior Approach. Arthroscopy. https://doi.org/10.1002/arj.70059
Vancouver
Ahn JH, Son DW. Posterior Approach Ramp Lesion Repair Using an All‐Inside Meniscal Repair Device in Hamstring Anterior Cruciate Ligament Reconstruction and Lateral Extra‐articular Tenodesis Shows Superior Healing Over Anterior Approach. Arthroscopy. 2026. doi:10.1002/arj.70059
BibTeX
@article{Ahn2026,
author = {Ahn, Ji Hyun and Son, Dong-Wook},
title = {Posterior Approach Ramp Lesion Repair Using an All‐Inside Meniscal Repair Device in Hamstring Anterior Cruciate Ligament Reconstruction and Lateral Extra‐articular Tenodesis Shows Superior Healing Over Anterior Approach},
journal = {Arthroscopy},
year = {2026},
doi = {10.1002/arj.70059}
}
EUVIMED