Thermo‐Mechanical Degradation Kinetics of a High‐Density Poly(Ethylene) Using a Closed‐Cavity Rheometer
Journal of Applied Polymer Science · 05.05.2025 · 142 (17)
DOI: 10.1002/app.56784 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Polymer Science, online erschienen am 23.01.2025. Verfasst von Tim Schülein und 4 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Mechanical recycling of polymers is an essential aspect to achieve circular economy. High shear stress, excessive temperature, and long residence time during reprocessing cause thermo‐mechanical degradation of the polymer. Therefore, it is important to understand and quantify this degradation kinetics. Common ways to simulate degradation are very time and material consuming and clear insights into the respective influence of temperature and shear stress on degradation are rare. Within this publication a method is developed using a commercially available, close‐cavity rheometer to emulate processing conditions in a defined way. This allows monitoring and predicting the behavior of a high‐density polyethylene (HDPE) and quantify degradation kinetics and changes in the polymer topology. HDPE is selected as a model polymer due to its large production and wide range of applications. Different treated samples are analyzed by various rheological methods. Additionally, molecular characterization is conducted. A kinetic model to predict the changes in the molecular weight as a function of in‐phase shear stress, temperature and duration during treatment is presented. The calculated activation energy for the initiation reaction agrees with the activation energy for HDPE degradation from thermogravimetric analysis. This activation energy is lowered by in‐phase shear stress, modified by a factor of 1.7 m 3 mol −1 .
Zitieren
APA
Schülein, T., Georgantopoulos, C. K., Bolk, L., Herrmann, V., & Wilhelm, M. (2025). Thermo‐Mechanical Degradation Kinetics of a High‐Density Poly(Ethylene) Using a Closed‐Cavity Rheometer. Journal of Applied Polymer Science, 142(17). https://doi.org/10.1002/app.56784
Vancouver
Schülein T, Georgantopoulos CK, Bolk L, Herrmann V, Wilhelm M. Thermo‐Mechanical Degradation Kinetics of a High‐Density Poly(Ethylene) Using a Closed‐Cavity Rheometer. Journal of Applied Polymer Science. 2025;142(17). doi:10.1002/app.56784
BibTeX
@article{Schlein2025,
author = {Schülein, Tim and Georgantopoulos, Christos K. and Bolk, Lars and Herrmann, Volker and Wilhelm, Manfred},
title = {Thermo‐Mechanical Degradation Kinetics of a High‐Density Poly(Ethylene) Using a Closed‐Cavity Rheometer},
journal = {Journal of Applied Polymer Science},
year = {2025},
volume = {142},
number = {17},
doi = {10.1002/app.56784}
}
EUVIMED