Design and optimization of air‐cooled supercapacitor thermal management system based on the corner deflectors and the inclined inlet and outlet
Asia-Pacific Journal of Chemical Engineering · 2024-09 · 19 (5)
DOI: 10.1002/apj.3104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asia-Pacific Journal of Chemical Engineering, online erschienen am 27.06.2024. Verfasst von Chaoying Xu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
In this paper, a novel air‐cooled supercapacitor thermal management system (STMS) based on the corner deflectors and the inclined inlet and outlet was proposed. The temperature and velocity fields were simulated and analyzed by CFD. Moreover, the heat dissipation effect of different STMSs was analyzed against each other. The results showed that the STMS proposed had a better heat dissipation effect when the inclined angle of inlet and outlet was appropriate, in which the maximum temperature ( T max ) and the maximum temperature difference ( ΔT max ) of the module could be reduced by 10.3% and 34.6%. And it is shown that the structure with inclined inlet and outlet plays an important role for the heat dissipation capability of the STMS proposed. And it has experimentally proven its heat dissipation ability. Consequently, the impacts of inclined angle ( α ), monomer spacing ( d c ), and the distance between monomer and module shell ( d x , d y , and d z ) on the heat dissipation effect were deeply analyzed. For the STMS arranged in four rows and three columns, it had a better heat dissipation effect when inclined angle was in the range of 40° to 50°. The results showed that the structural parameters had a large influence on the T max and ΔT max . Besides, it had shown that the temperature curves of the T max and ΔT max had a main trend of “decreasing and then increasing” when the monomer spacing as well as the distance between monomer and module shell are taken from 1 mm to 5 mm. It implies that a small spacing (1 mm to 2 mm) will hinder the air circulation and reduce heat dissipation, and a large spacing (3 mm to 5 mm) will reduce the average flow rate of air and reduce the efficiency of heat transfer.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xu, C., Li, G., & Ruan, D. (2024). Design and optimization of air‐cooled supercapacitor thermal management system based on the corner deflectors and the inclined inlet and outlet. Asia-Pacific Journal of Chemical Engineering, 19(5). https://doi.org/10.1002/apj.3104
Vancouver
Xu C, Li G, Ruan D. Design and optimization of air‐cooled supercapacitor thermal management system based on the corner deflectors and the inclined inlet and outlet. Asia-Pacific Journal of Chemical Engineering. 2024;19(5). doi:10.1002/apj.3104
BibTeX
@article{Xu2024,
author = {Xu, Chaoying and Li, Guofu and Ruan, Dianbo},
title = {Design and optimization of air‐cooled supercapacitor thermal management system based on the corner deflectors and the inclined inlet and outlet},
journal = {Asia-Pacific Journal of Chemical Engineering},
year = {2024},
volume = {19},
number = {5},
doi = {10.1002/apj.3104}
}
EUVIMED