Self‐Recognizing L‐Glutamine‐Conjugated Manganese Oxide Sensors for Salivary Microdroplet Analysis
Analysis & Sensing · 2026-01 · 6 (1)
DOI: 10.1002/anse.202500092 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analysis & Sensing, online erschienen am 23.08.2025. Verfasst von Muhammad Shahid und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben.
Abstract (Originalsprache)
Early detection of Alzheimer's disease (AD) remains a critical challenge in neurodiagnostics that necessitates the development of noninvasive, cost‐effective, and reliable biosensing platforms. Herein, a self‐recognizing L‐glutamine‐conjugated manganese oxide (Gln‐MnO 2 )‐modified electrode is developed for the electrochemical detection of L‐glutamine (Gln) in a microdroplet of human saliva, a potential biomarker for early‐stage AD. The biofunctionalized MnO 2 interface facilitates hydrogen bonding and electrostatic interactions with Gln, eliminating the need for enzymatic recognition elements while enhancing its sensitivity. Electrochemical characterization demonstrates a reversible, adsorption‐controlled redox process with an electroactive surface area of 0.225 cm 2 , high sensitivity (3.16 µA cm −2 nM −1 ), and a low detection limit (69.7 pM). Real saliva analysis confirms its practical utility, with measured Gln concentrations (6.70 ± 0.93 µM) aligning with reported physiological levels. Furthermore, standard addition experiments yield a recovery of 94.67 ± 5.14%, which also validates its accuracy. The Gln‐MnO 2 sensor exhibits excellent operational stability over 15 days, with minimal signal loss afterward due to nonspecific adsorption in complex biofluids. The developed platform offers a cost‐effective, enzyme‐free, and disposable sensing approach for AD biomarker detection, with potential applications in metabolic monitoring and point‐of‐care diagnostics.
Zitieren
APA
Shahid, M., Rizvi, S. N. B., & Afzal, A. (2026). Self‐Recognizing L‐Glutamine‐Conjugated Manganese Oxide Sensors for Salivary Microdroplet Analysis. Analysis & Sensing, 6(1). https://doi.org/10.1002/anse.202500092
Vancouver
Shahid M, Rizvi SNB, Afzal A. Self‐Recognizing L‐Glutamine‐Conjugated Manganese Oxide Sensors for Salivary Microdroplet Analysis. Analysis & Sensing. 2026;6(1). doi:10.1002/anse.202500092
BibTeX
@article{Shahid2026,
author = {Shahid, Muhammad and Rizvi, Syeda Nayab Batool and Afzal, Adeel},
title = {Self‐Recognizing L‐Glutamine‐Conjugated Manganese Oxide Sensors for Salivary Microdroplet Analysis},
journal = {Analysis & Sensing},
year = {2026},
volume = {6},
number = {1},
doi = {10.1002/anse.202500092}
}
EUVIMED