EUVIMEDEUVIMED entdecken
Open Access

Position of catheter‐through‐needle erector spinae plane catheters for rib fracture analgesia assessed by computed tomography

B Goulson, F Malik, N Suarez iD, M Luney

Anaesthesia Reports · 2026-01 · 14 (1)

DOI: 10.1002/anr3.70079 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Anaesthesia Reports, online erschienen am 21.06.2026. Verfasst von B Goulson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nuffield Department of Anaesthesia Oxford University Hospitals NHS Foundation Trust Oxford UK. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Erector spinae plane catheters are increasingly used for rib fracture analgesia, but the influence of catheter insertion technique on catheter position and analgesic effectiveness remains uncertain. In this case series, we describe 11 erector spinae plane catheters inserted using a catheter‐through‐needle technique for analgesia in patients with rib fractures who underwent chest computed tomography after catheter insertion. Catheter tip position outside the intended fascial plane was identified in six of 11 (55%) catheters. Previous studies of catheter‐over‐needle systems have reported displacement rates of up to 89%, but cross‐study comparisons are limited by small sample sizes and differences in population, catheter techniques and imaging protocols. Interpretation of clinical impact is limited. Pain score recording and analgesic prescribing were not standardised, and patients frequently had multiple injuries requiring multimodal analgesia, making it difficult to isolate the contribution of erector spinae planes catheter position to pain relief. Furthermore, computed tomography demonstrates catheter location but may not reflect local anaesthetic spread or functional block efficacy. These findings highlight clinically relevant uncertainty regarding the relationship between catheter insertion technique, catheter position and patient‐centred analgesic effectiveness. Further prospective studies are needed to determine whether insertion techniques affect catheter position, injectate spread and patient‐centred analgesic outcomes.

Schlagwörter

Stichwörter der Autor:innen

catheter displacementcatheter‐through‐needlecomputed tomographyerector spinae plane blockrib fractures

Autor:innen und Institutionen

  • Nuffield Department of Anaesthesia Oxford University Hospitals NHS Foundation Trust Oxford UK.
  • Department of Radiology Oxford University Hospitals NHS Foundation Trust Oxford UK.
  • Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK.
  • Kadoorie Institute, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford Oxford UK.

ORCID-Profile: N Suarez

Zitieren

APA

Goulson, B., Malik, F., Suarez, N., & Luney, M. (2026). Position of catheter‐through‐needle erector spinae plane catheters for rib fracture analgesia assessed by computed tomography. Anaesthesia Reports, 14(1). https://doi.org/10.1002/anr3.70079

Vancouver

Goulson B, Malik F, Suarez N, Luney M. Position of catheter‐through‐needle erector spinae plane catheters for rib fracture analgesia assessed by computed tomography. Anaesthesia Reports. 2026;14(1). doi:10.1002/anr3.70079

BibTeX
@article{Goulson2026,
  author = {Goulson, B and Malik, F and Suarez, N and Luney, M},
  title = {Position of catheter‐through‐needle erector spinae plane catheters for rib fracture analgesia assessed by computed tomography},
  journal = {Anaesthesia Reports},
  year = {2026},
  volume = {14},
  number = {1},
  doi = {10.1002/anr3.70079}
}
Kostenlos starten →