EUVIMEDEUVIMED entdecken
Leserbrief

Reply to the Correspondence on “Carbon‐Dot‐Based Dual‐Emission Nanohybrid Produces a Ratiometric Fluorescent Sensor for in Vivo Imaging of Cellular Copper Ions”

Anwei Zhu iD, Yang Tian iD

Angewandte Chemie International Edition · 11.05.2026 · 65 (20)

DOI: 10.1002/anie.9981178 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 05.04.2026. Verfasst von Anwei Zhu und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, P. R. China. Die Arbeit nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Correspondence by Gharib et al. challenges our 2012 study on CQD‐based Cu 2+ sensors but introduces no new experimental data. Their failure to reproduce our results stems directly from fundamental errors in materials synthesis. Specifically, they failed to properly synthesize either key material. Regarding AE‐TPEA, the core innovation of our work, they deviated from our published protocol, failed to synthesize and validate the identity and purity of the product, and did not report the deviation from the protocol in the Correspondence. Without authentic AE‐TPEA, the subsequent experiments are scientifically meaningless. Regarding CQDs, we followed the established method of Li et al., a protocol independently reproduced by numerous laboratories worldwide. The authors failed to synthesize the proper fluorescent CQDs because they did not strictly follow the experimental conditions, not because of a flaw in our approach. Furthermore, their own data are internally inconsistent. Three parallel syntheses yielded conflicting results across UV‐vis, fluorescence, FTIR, TEM, DLS, and zeta potential measurements, exposing a lack of experimental control. Finally, our work has been widely validated. Over a decade of independent applications, many research groups have confirmed the reproducibility and utility of our approach.

Autor:innen und Institutionen

  • School of Chemistry and Molecular Engineering, East China Normal University, Shanghai, P. R. China.

ORCID-Profile: Anwei Zhu, Yang Tian

Zitieren

APA

Zhu, A., & Tian, Y. (2026). Reply to the Correspondence on “Carbon‐Dot‐Based Dual‐Emission Nanohybrid Produces a Ratiometric Fluorescent Sensor for in Vivo Imaging of Cellular Copper Ions”. Angewandte Chemie International Edition, 65(20). https://doi.org/10.1002/anie.9981178

Vancouver

Zhu A, Tian Y. Reply to the Correspondence on “Carbon‐Dot‐Based Dual‐Emission Nanohybrid Produces a Ratiometric Fluorescent Sensor for in Vivo Imaging of Cellular Copper Ions”. Angewandte Chemie International Edition. 2026;65(20). doi:10.1002/anie.9981178

BibTeX
@article{Zhu2026,
  author = {Zhu, Anwei and Tian, Yang},
  title = {Reply to the Correspondence on “Carbon‐Dot‐Based Dual‐Emission Nanohybrid Produces a Ratiometric Fluorescent Sensor for in Vivo Imaging of Cellular Copper Ions”},
  journal = {Angewandte Chemie International Edition},
  year = {2026},
  volume = {65},
  number = {20},
  doi = {10.1002/anie.9981178}
}
Kostenlos starten →