EUVIMEDEUVIMED entdecken
Crossref

Resolving the Sensitivity–Specificity Trade‐Off in Fluorescent Probes via a Tandem‐Activatable Shielding Strategy

Lidong Du, Haoran Ma, Wenshan Yan, Hanchen Shen, Qingqing Zhou, Moxin Li, Manxiong Dai, Dongfeng Dang iD, Ruiyu Xie iD, Tzu-Ming Liu iD, Changhuo Xu iD

Angewandte Chemie International Edition · 16.11.2026 · 65 (47)

DOI: 10.1002/anie.9882356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 10.10.2026. Verfasst von Lidong Du und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Sciences, Faculty of Medicine, University of Macau, Macau, China. Hauptthemen laut MEDLINE: Fluorescent Dyes. Die Arbeit nennt 65 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Development Fund of Macau SAR, University of Macau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For precise tumor diagnosis, the intrinsic trade‐off between sensitivity and specificity in fluorescent probes remains a longstanding bottleneck, underscoring an urgent need for strategies to break this fundamental constraint. To address the specificity limitation, we exploited a highly polarity‐sensitive fluorescent scaffold to construct a tandem‐activatable probe, enabling sequential activation by the acidic tumor microenvironment and the angiogenic marker aminopeptidase N. Whereas the single‐locked counterpart is prone to premature activation in circulation, the tandem‐locked probe remains inactive owing to a maleamic acid‐based shielding unit and is activated only upon encountering these two tumor hallmarks. Furthermore, this shielding strategy increases probe hydrophobicity, enhancing tumor uptake and driving accumulation of released fluorophores in low‐polarity lipid droplets, where fluorescence is markedly amplified to improve imaging sensitivity. The probe exhibits rapid and specific activation across various solid tumors with minimal toxicity, thus effectively resolving the sensitivity‐specificity trade‐off in probe design for in vivo applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesHumansAnimalsTumor MicroenvironmentFluorescent Chemosensor CompoundsMiceOptical Imaging

Stichwörter der Autor:innen

fluorescent probehigh sensitivitymicroenvironmental polaritytandem activationtumor targeted imaging

Substanzen

Fluorescent DyesFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Department of Biomedical Sciences, Faculty of Medicine, University of Macau, Macau, China.
  • Innovative Center for Flexible Devices (iFLEX), Max Planck-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore.
  • School of Chemistry, Engineering Research Center of Energy Storage Materials and Devices, Xi'an Key Laboratory of Sustainable Polymer Materials, Xi'an Jiaotong University, Xi'an, China.

ORCID-Profile: Dongfeng Dang, Ruiyu Xie, Tzu-Ming Liu, Changhuo Xu

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Development Fund of Macau SAR
  • University of Macau
  • Universidade de Macau

Zitieren

APA

Du, L., Ma, H., Yan, W., Shen, H., Zhou, Q., Li, M., Dai, M., Dang, D., Xie, R., Liu, T. M., & Xu, C. (2026). Resolving the Sensitivity–Specificity Trade‐Off in Fluorescent Probes via a Tandem‐Activatable Shielding Strategy. Angewandte Chemie International Edition, 65(47). https://doi.org/10.1002/anie.9882356

Vancouver

Du L, Ma H, Yan W, Shen H, Zhou Q, Li M, et al. Resolving the Sensitivity–Specificity Trade‐Off in Fluorescent Probes via a Tandem‐Activatable Shielding Strategy. Angewandte Chemie International Edition. 2026;65(47). doi:10.1002/anie.9882356

BibTeX
@article{Du2026,
  author = {Du, Lidong and Ma, Haoran and Yan, Wenshan and Shen, Hanchen and Zhou, Qingqing and Li, Moxin and Dai, Manxiong and Dang, Dongfeng and Xie, Ruiyu and Liu, Tzu-Ming and Xu, Changhuo},
  title = {Resolving the Sensitivity–Specificity Trade‐Off in Fluorescent Probes via a Tandem‐Activatable Shielding Strategy},
  journal = {Angewandte Chemie International Edition},
  year = {2026},
  volume = {65},
  number = {47},
  doi = {10.1002/anie.9882356}
}
Kostenlos starten →