EUVIMEDEUVIMED entdecken
Crossref

Balancing pH Mismatch in Electrolytic Zn‐MnO 2 Batteries via a Synergetic Anion–Proton Interactive Electrolyte

Peiyan Tong, Mingming Wang, Shunxin Tan iD, Dongyang Shen iD, Ruihao Luo, Taoli Jiang iD, Guili Zhao iD, Hongxu Liu iD, Zuodong Zhang, Yidi Wang iD, Zhenshan Lv, Hao Cheng iD und 3 weitere

Angewandte Chemie International Edition · 05.10.2026 · 65 (41)

DOI: 10.1002/anie.5238065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 13.08.2026. Verfasst von Peiyan Tong und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Chemistry, School of Chemistry and Materials Science, Hefei National Research Center for Physical Sciences At the Microscale, U…. Die Arbeit nennt 60 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, subaward from KAUST Center of Excellence for Renewable Energy and Storage Technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrolytic Zn‐MnO 2 batteries (EZMBs) are considered a promising technology for grid‐scale energy storage due to their low cost, high specific capacity, high operating voltage and safety. However, the tradeoff between the mildly acidic environment for high‐efficiency zinc deposition on anode and the high concentration of protons required to trigger the MnO 2 /Mn 2+ conversion reaction on cathode leads to the pH mismatch issue, finally causing the instability and short lifespan of current EZMBs. In this study, a synergetic anion–proton interactive (SAPI) electrolyte regulation strategy is reported to balance the pH mismatch, which can not only regulate the electrode‐electrolyte interfacial microenvironment to promote the deposition of highly (002)‐oriented Zn plane with high resistance to the hydrogen evolution reaction and corrosion on anode, but also accelerate the redox reaction of MnO 2 /Mn 2+ conversion on cathode, simultaneously. As a result, the SAPI electrolyte enables a 40‐fold lifespan enhancement of over 5000 cycles at a current density of 10 mA cm −2 in Zn‐Zn symmetric cells as compared to the pristine electrolyte. Furthermore, the EZMBs in SAPI electrolyte achieve an elevated average discharge voltage of 0.4 V and about 10‐fold stable cycling lifespan than the pristine one. This strategy provides novel insights into designing long‐life EZMBs and orientational deposition of zinc anode.

Schlagwörter

Stichwörter der Autor:innen

dendrite growth inhibitionelectrolytic Zn‐MnO2 batteryorientational Zn depositionsynergetic anion–proton interactive electrolytezinc metal anode

Autor:innen und Institutionen

  • Department of Applied Chemistry, School of Chemistry and Materials Science, Hefei National Research Center for Physical Sciences At the Microscale, University of Science and Technology of China, Hefei, Anhui, China.
  • School of Chemistry and Materials Science, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences (UCAS), Hangzhou, China.
  • Zhejiang Key Laboratory of Intelligent Manufacturing For Functional Chemicals, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, China.
  • State Key Laboratory of New Textile Materials and Advanced Processing, Wuhan Textile University, Wuhan, China.
  • Hefei National Laboratory, University of Science and Technology of China, Hefei, Anhui, China.

ORCID-Profile: Shunxin Tan, Dongyang Shen, Taoli Jiang, Guili Zhao, Hongxu Liu, Yidi Wang, Hao Cheng, Mingjie Wu, Wei Chen

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • subaward from KAUST Center of Excellence for Renewable Energy and Storage Technologies
  • State Key Laboratory of New Textile Materials and Advanced Processing, Wuhan Textile University
  • Innovation Program for Quantum Science and Technology

Zitieren

APA

Tong, P., Wang, M., Tan, S., Shen, D., Luo, R., Jiang, T., Zhao, G., Liu, H., Zhang, Z., Wang, Y., Lv, Z., Cheng, H., Wu, M., Li, X., & Chen, W. (2026). Balancing pH Mismatch in Electrolytic Zn‐MnO 2 Batteries via a Synergetic Anion–Proton Interactive Electrolyte. Angewandte Chemie International Edition, 65(41). https://doi.org/10.1002/anie.5238065

Vancouver

Tong P, Wang M, Tan S, Shen D, Luo R, Jiang T, et al. Balancing pH Mismatch in Electrolytic Zn‐MnO 2 Batteries via a Synergetic Anion–Proton Interactive Electrolyte. Angewandte Chemie International Edition. 2026;65(41). doi:10.1002/anie.5238065

BibTeX
@article{Tong2026,
  author = {Tong, Peiyan and Wang, Mingming and Tan, Shunxin and Shen, Dongyang and Luo, Ruihao and Jiang, Taoli and Zhao, Guili and Liu, Hongxu and Zhang, Zuodong and Wang, Yidi and Lv, Zhenshan and Cheng, Hao and Wu, Mingjie and Li, Xiangyang and Chen, Wei},
  title = {Balancing pH Mismatch in Electrolytic Zn‐MnO 2 Batteries via a Synergetic Anion–Proton Interactive Electrolyte},
  journal = {Angewandte Chemie International Edition},
  year = {2026},
  volume = {65},
  number = {41},
  doi = {10.1002/anie.5238065}
}
Kostenlos starten →