Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring
Angewandte Chemie International Edition · 26.10.2026 · 65 (44)
DOI: 10.1002/anie.3323663 ↗Kurz gefasst
Fachartikel in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 08.09.2026. Verfasst von Mingzhu Yang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Advanced Materials, College of Smart Materials and Future Energy, Department of Chemistry, New Cornerstone Science Laboratory, State Ke…. Hauptthemen laut MEDLINE: Cerium, Thermometers, Temperature, Thermometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Research Program of Science and Technology Commission of Shanghai Municipality, New Cornerstone Science Foundation.
Abstract (Originalsprache)
Precise temperature monitoring in living systems provides valuable insights into physiological processes, thereby motivating the development of luminescent nanothermometers for noninvasive thermometry. However, wavelength‐dependent tissue absorption and scattering inevitably distort luminescence signals, resulting in inaccurate temperature measurements. Here, we report a self‐calibrating luminescent nanothermometer (NaYF 4 : Tm@NaYF 4 : Er@NaYF 4 @NaYbF 4 : Er/Tm/Ce@NaYF 4 ) that utilizes the Er 3+ and Tm 3+ emissions at 1532 and 1626 nm in the low‐scattering long‐wavelength near‐infrared region (NIR‐II‐L, 1500–1900 nm) to achieve reliable in vivo thermometry. By identifying Ce 3+ as a critical mediator that suppresses temperature‐sensitive phonon‐assisted energy transfer (PAT) between Tm 3+ and Er 3+ , we inversely engineered the Ce 3+ ‐doped Tm 3+ /Er 3+ outer module to generate a thermally inert reference ratio for calibrating the PAT‐enhanced thermometric ratio of the inner Tm 3+ /Er 3+ module. The resulting self‐calibrating signal minimized depth‐induced distortion with only 2.9% fluctuation through 10 mm of tissue, enabling reliable dynamic thermometry at a high temporal resolution of 20 fps. In vivo studies further demonstrated that the nanothermometer enabled accurate intestinal thermometry and intratumoral temperature monitoring during photothermal therapy. This work provides new insights into self‐calibrating luminescent nanoprobes for accurate real‐time sensing in living systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Advanced Materials, College of Smart Materials and Future Energy, Department of Chemistry, New Cornerstone Science Laboratory, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Labora…
- Science and Technology Innovation Center, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, P. R. China.
ORCID-Profile: Zi-Han Chen, Jiang Ming, Zhihua Wang, Hongxin Zhang, Fan Zhang
Förderung
- National Natural Science Foundation of China
- Research Program of Science and Technology Commission of Shanghai Municipality
- New Cornerstone Science Foundation
- Innovation Program of Shanghai Municipal Education Commission
- Innovative Special Project for the Integration of Science and Education
- National Key R&D Program of China
- China Postdoctoral Science Foundation
Zitieren
APA
Yang, M., Chen, Z. H., Liu, H., Xu, J., Ming, J., Yu, Z., Wang, X., Yun, B., Wang, X., Wang, Z., Zhang, H., & Zhang, F. (2026). Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring. Angewandte Chemie International Edition, 65(44). https://doi.org/10.1002/anie.3323663
Vancouver
Yang M, Chen ZH, Liu H, Xu J, Ming J, Yu Z, et al. Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring. Angewandte Chemie International Edition. 2026;65(44). doi:10.1002/anie.3323663
BibTeX
@article{Yang2026,
author = {Yang, Mingzhu and Chen, Zi-Han and Liu, Hongyue and Xu, Jing and Ming, Jiang and Yu, Zhenfeng and Wang, Xusheng and Yun, Baofeng and Wang, Xiaohan and Wang, Zhihua and Zhang, Hongxin and Zhang, Fan},
title = {Ce 3+ ‐Mediated Self‐Calibrating NIR‐II Nanothermometer Enables Reliable Real‐Time In Vivo Temperature Monitoring},
journal = {Angewandte Chemie International Edition},
year = {2026},
volume = {65},
number = {44},
doi = {10.1002/anie.3323663}
}
EUVIMED