Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering
Angewandte Chemie International Edition · 06.04.2026 · 65 (15)
DOI: 10.1002/anie.202522980 ↗Kurz gefasst
Fachartikel in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 29.12.2025. Verfasst von Sujit K Das und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Sciences, Tata Institute of Fundamental Research, Mumbai, Maharashtra, 400005, India. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Department of Atomic Energy, Government of India, JST-COI-NEXT.
Abstract (Originalsprache)
Raman‐scattering comes with the promise of multi‐bio‐analyte imaging because of narrow peak‐widths. This feature combined with alkyne/nitrile tags accessing the cell‐silent region, have catalyzed the development of Raman‐probes. In this backdrop, Raman‐responsive ratiometric sensors will be key players for imaging bio‐analytes. A major challenge, however, is low Raman‐scattering cross‐sections of alkynes/nitriles, leading to probes with low sensitivity and reliance on stimulated Raman which is not widely accessible. Raman‐responsive ratiometric sensors for the accessible spontaneous Raman imaging platform still remain elusive. We have leveraged the “push–pull” effect to achieve novel activity‐based alkyne‐tag Raman sensors ( ABATaR s) with high sensitivity. ABATaR s show high computed Raman‐scattering activities 12–38 times that of benchmark 5‐Ethynyl‐2′‐deoxyuridine ( EdU ), significantly high experimental Raman intensity versus EdU between 5 and 22, and relative Raman scattering cross‐sections for the alkyne stretching with respect to dimethyl‐sulfoxide C‐H stretching as high as 466. To demonstrate generality, cell‐permeable, ratiometric ABATaR s for pH, hydrogen peroxide, and Cu ions were developed. ABATaR s can image physiological and pathophysiological levels of bio‐analytes in live‐cells at as low as 1–5 µM sensor concentrations on a spontaneous Raman microscope and distinctly enhance spontaneous Raman imaging‐speed. In a key advance, we demonstrate simultaneous multi‐analyte Raman‐imaging of bio‐correlated Cu ions and hydrogen peroxide in live‐cells.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical Sciences, Tata Institute of Fundamental Research, Mumbai, Maharashtra, 400005, India.
- Department of Applied Physics, The University of Osaka, Suita, Osaka, 565-0871, Japan.
- Institute for Open and Transdisciplinary Research Initiatives, The University of Osaka, Suita, Osaka, 565-0871, Japan.
ORCID-Profile: Sujit K Das, Heqi Xi, Katsumasa Fujita, Ankona Datta
Förderung
- Department of Atomic Energy, Government of India
- JST-COI-NEXT
Zitieren
APA
Das, S. K., Xi, H., Yamamoto, I., Fujita, K., & Datta, A. (2026). Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering. Angewandte Chemie International Edition, 65(15). https://doi.org/10.1002/anie.202522980
Vancouver
Das SK, Xi H, Yamamoto I, Fujita K, Datta A. Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering. Angewandte Chemie International Edition. 2026;65(15). doi:10.1002/anie.202522980
BibTeX
@article{Das2026,
author = {Das, Sujit K and Xi, Heqi and Yamamoto, Itsuki and Fujita, Katsumasa and Datta, Ankona},
title = {Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering},
journal = {Angewandte Chemie International Edition},
year = {2026},
volume = {65},
number = {15},
doi = {10.1002/anie.202522980}
}
EUVIMED