EUVIMEDEUVIMED entdecken
Open Access

Reversible and Ultrasensitive Detection of Nitric Oxide Using a Conductive Two‐Dimensional Metal–Organic Framework

Hyuk-Jun Noh, Doran L Pennington, Jeong-Min Seo, Evan Cline, Georganna Benedetto, Jong-Beom Baek, Christopher H Hendon, Katherine A Mirica iD

Angewandte Chemie International Edition · 10.02.2025 · 64 (7)

DOI: 10.1002/anie.202419869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, online erschienen am 02.12.2024. Verfasst von Hyuk-Jun Noh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Dartmouth College, Burke Laboratory, Hanover, New Hampshire, 03755, United States. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 93 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Directorate for Mathematical and Physical Sciences, Cold Regions Research and Engineering Laboratory, NIEHS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper describes the use of a highly crystalline conductive 2D copper 3 (hexaiminobenzene) 2 (Cu 3 (HIB) 2 ) as an ultrasensitive (limit of detection of 1.8 part‐per‐billion), highly selective, reversible, and low power chemiresistive sensor for nitric oxide (NO) at room temperature. The Cu 3 (HIB) 2 ‐based sensors retain their sensing performance in the presence of humidity, and exhibit strong signal enhancement towards NO over other highly toxic reactive gases, such as NO 2 , H 2 S, SO 2 , NH 3 , CO, as well as CO 2 . Mechanistic investigations of the Cu 3 (HIB) 2 ‐NO interaction through spectroscopic analyses and density functional theory revealed that the Cu‐bis(iminobenzosemiquinoid) moieties serve as the binding sites for NO sensing, while the Ni‐bis(iminobenzosemiquinoid) MOF analog shows no noticeable response to NO. Overall, these findings provide a significant advance in the development of crystalline metal‐bis(iminobenzosemiquinoid)‐based conductive 2D MOFs as highly sensitive, selective, and reversible sensing materials for the low‐power detection of toxic gases.

Schlagwörter

Stichwörter der Autor:innen

Chemiresistive SensorConductivityMetal–Organic FrameworkNitric OxideTwo Dimensional

Autor:innen und Institutionen

  • Department of Chemistry, Dartmouth College, Burke Laboratory, Hanover, New Hampshire, 03755, United States.
  • Department of Chemistry and Biochemistry, University of Oregon, Oregon, 97403, United States.
  • School of Energy and Chemical Engineering/Center for Dimension-Controllable Organic Frameworks, Ulsan National Institute of Science and Technology (UNIST) 50 UNIST-gil, Ulsan, 44919, Republic of Korea.

ORCID-Profile: Katherine A Mirica

Förderung

  • Directorate for Mathematical and Physical Sciences
  • Cold Regions Research and Engineering Laboratory
  • NIEHS NIH HHS
  • NIGMS NIH HHS
  • Camille and Henry Dreyfus Foundation
  • Division of Materials Research
  • National Research Foundation of Korea
  • CLC NIH HHS

Zitieren

APA

Noh, H. J., Pennington, D. L., Seo, J. M., Cline, E., Benedetto, G., Baek, J. B., Hendon, C. H., & Mirica, K. A. (2025). Reversible and Ultrasensitive Detection of Nitric Oxide Using a Conductive Two‐Dimensional Metal–Organic Framework. Angewandte Chemie International Edition, 64(7). https://doi.org/10.1002/anie.202419869

Vancouver

Noh HJ, Pennington DL, Seo JM, Cline E, Benedetto G, Baek JB, et al. Reversible and Ultrasensitive Detection of Nitric Oxide Using a Conductive Two‐Dimensional Metal–Organic Framework. Angewandte Chemie International Edition. 2025;64(7). doi:10.1002/anie.202419869

BibTeX
@article{Noh2025,
  author = {Noh, Hyuk-Jun and Pennington, Doran L and Seo, Jeong-Min and Cline, Evan and Benedetto, Georganna and Baek, Jong-Beom and Hendon, Christopher H and Mirica, Katherine A},
  title = {Reversible and Ultrasensitive Detection of Nitric Oxide Using a Conductive Two‐Dimensional Metal–Organic Framework},
  journal = {Angewandte Chemie International Edition},
  year = {2025},
  volume = {64},
  number = {7},
  doi = {10.1002/anie.202419869}
}
Kostenlos starten →