EUVIMEDEUVIMED entdecken
Crossref

A Single Set of Well‐Designed Aptamer Probes for Reliable On‐site Qualitative and Ultra‐Sensitive Quantitative Detection

Wei-Qi Zhang iD, Yi-Dan Tu, Hong Liu, Rui Liu, Xiao-Jin Zhang, Lei Jiang, Yu Huang iD, Fan Xia iD

Angewandte Chemie International Edition · 2024

DOI: 10.1002/anie.202316434 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, 2024. Verfasst von Wei-Qi Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of M…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Basic Research Program of China, Natural Science Foundation of Hubei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aptamer‐based probes are pivotal components in various sensing strategies, owing to their exceptional specificity and versatile programmable structure. Nevertheless, numerous aptamer‐based probes usually offer only a single function, limiting their capacity to meet the diverse requirements of multi‐faceted sensing systems. Here, we introduced supersandwich DNA probes (SSW‐DNA), designed and modified on the outer surface of nanochannels with hydrophobic inner walls, enabling dual functionality: qualitative detection for on‐site analysis and quantitative detection for precise analysis. The fragmented DNAs resulting from the target recognition, are subsequently identified through lateral flow assays, enabling robust on‐site qualitative detection of microcystin‐LR with an impressively low limit of detection (LOD) at 0.01 μg/L. Meanwhile, the nanochannels enable highly sensitive quantification of microcystin‐LR through the current analysis, achieving an exceptionally low LOD at 2.5×10 −7 μg/L, with a broad dynamic range spanning from 1×10 −6 to 1×10 2 μg/L. Furthermore, the process of target recognition introduces just a single potential error propagation, which reduces the overall risk of errors during the entire qualitative and quantitative detection process. This sensing strategy broadens the scope of applications for aptamer‐based composite probes, holding promising implications across diverse fields, such as medical diagnosis, food safety, and environmental protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesDNA ProbesDNALimit of Detection

Stichwörter der Autor:innen

AptamerIonic CurrentSolid-State NanochannelSupersandwich DNAWettability

Substanzen

Aptamers, NucleotideDNA ProbesDNA

Autor:innen und Institutionen

  • State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan,…
  • CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China.

ORCID-Profile: Wei-Qi Zhang, Yu Huang, Fan Xia

Förderung

  • National Natural Science Foundation of China
  • National Basic Research Program of China
  • Natural Science Foundation of Hubei Province
  • National Key Research and Development Program of China

Zitieren

APA

Zhang, W. Q., Tu, Y. D., Liu, H., Liu, R., Zhang, X. J., Jiang, L., Huang, Y., & Xia, F. (2024). A Single Set of Well‐Designed Aptamer Probes for Reliable On‐site Qualitative and Ultra‐Sensitive Quantitative Detection. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202316434

Vancouver

Zhang WQ, Tu YD, Liu H, Liu R, Zhang XJ, Jiang L, et al. A Single Set of Well‐Designed Aptamer Probes for Reliable On‐site Qualitative and Ultra‐Sensitive Quantitative Detection. Angewandte Chemie International Edition. 2024. doi:10.1002/anie.202316434

BibTeX
@article{Zhang2024,
  author = {Zhang, Wei-Qi and Tu, Yi-Dan and Liu, Hong and Liu, Rui and Zhang, Xiao-Jin and Jiang, Lei and Huang, Yu and Xia, Fan},
  title = {A Single Set of Well‐Designed Aptamer Probes for Reliable On‐site Qualitative and Ultra‐Sensitive Quantitative Detection},
  journal = {Angewandte Chemie International Edition},
  year = {2024},
  doi = {10.1002/anie.202316434}
}
Kostenlos starten →